In this paper, a dynamic model for an artificial finger driven by Shape Memory Alloy (SMA) wires is presented. Due to their high energy density, these alloys permit the realization of highly compact actuation solutions with potential applications in many areas of robotics, ranging from industrial to biomedical ones. Despite many advantages, SMAs exhibit a highly nonlinear and hysteretic behavior which complicates system design, modeling, and control. In case SMA wires are used to activate complex robotic systems, the further kinematic nonlinearities and contact problems make the modeling significantly more challenging. In this paper, we present a finite element model for a finger prototype actuated by a bundle of SMA wires. The commercially available software COMSOL is used to couple the finger structure with the SMA material, described via the Muller-Achenbach-Seelecke model. By means of several experiments, it is demonstrated how the model reproduces the finger response for different control inputs and actuator geometries.

Finite element modeling and simulation of a robotic finger actuated by Ni-Ti shape memory alloy wires

Meli Daniele;
2019-01-01

Abstract

In this paper, a dynamic model for an artificial finger driven by Shape Memory Alloy (SMA) wires is presented. Due to their high energy density, these alloys permit the realization of highly compact actuation solutions with potential applications in many areas of robotics, ranging from industrial to biomedical ones. Despite many advantages, SMAs exhibit a highly nonlinear and hysteretic behavior which complicates system design, modeling, and control. In case SMA wires are used to activate complex robotic systems, the further kinematic nonlinearities and contact problems make the modeling significantly more challenging. In this paper, we present a finite element model for a finger prototype actuated by a bundle of SMA wires. The commercially available software COMSOL is used to couple the finger structure with the SMA material, described via the Muller-Achenbach-Seelecke model. By means of several experiments, it is demonstrated how the model reproduces the finger response for different control inputs and actuator geometries.
2019
9781510625914
Shape Memory alloy
SMA
SMA activated finger
smart structure
Finite element simulation
Prosthetic hand
File in questo prodotto:
File Dimensione Formato  
FiniteElementModelingandSimulationofaRoboticFingerActuatedbyNi-TiShapeMemoryAlloyWires.pdf

accesso aperto

Licenza: Non specificato
Dimensione 666.31 kB
Formato Adobe PDF
666.31 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1093726
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact