An impedometric method for estimating the microbial load of ready-to-use vegetables, either inoculated or not inoculated with antimicrobial-producing lactic acid bacteria, was investigated. The correlation (R2) between total mesophilic bacteria (log cfu/g) and time to detection was 0.889. A discrepancy was observed for the impedometric measurement of low coliforms counts, particularly in samples inoculated with lactic acid bacteria and stored at 8°C for 6 days. Time to detection for the two groups of microorganisms was less than 11 h

Impedance measurements to assess microbial contamination of ready-to-use vegetables

TORRIANI, Sandra;
1997-01-01

Abstract

An impedometric method for estimating the microbial load of ready-to-use vegetables, either inoculated or not inoculated with antimicrobial-producing lactic acid bacteria, was investigated. The correlation (R2) between total mesophilic bacteria (log cfu/g) and time to detection was 0.889. A discrepancy was observed for the impedometric measurement of low coliforms counts, particularly in samples inoculated with lactic acid bacteria and stored at 8°C for 6 days. Time to detection for the two groups of microorganisms was less than 11 h
1997
Impedometry, Microbial contamination, Ready-to-use vegetables
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/430383
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 7
social impact