Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons. In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled in two PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818. After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin's fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.
Development of two new Mini-STR multiplex assay for typing archival Bouin's fluid-fixed paraffin-embedded tissues
TURRINA, Stefania;FILIPPINI, Giulia;DE LEO, Domenico
2009-01-01
Abstract
Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons. In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled in two PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818. After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin's fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.File | Dimensione | Formato | |
---|---|---|---|
Development of two new Mini-STR multiplexes assay for typing archival Bouin s fluid fixed paraffin embedded tissues.pdf
solo utenti autorizzati
Tipologia:
Documento in Post-print
Licenza:
Accesso ristretto
Dimensione
234.72 kB
Formato
Adobe PDF
|
234.72 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.