PURPOSE: To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes with corneal graft and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), and astigmatism on these methods. DESIGN: Prospective, observational cross-sectional study. METHODS: Eighteen eyes of 18 patients after penetrating keratoplasty (PKP) and 14 eyes of 14 patients after deep lamellar keratoplasty (DLKP) underwent IOP evaluation with DCT and GAT, and measurements of CCT, CC, and astigmatism. Bland-Altman plots were used to evaluate the agreement between tonometers. Multivariate regression analysis was used to evaluate the influence of ocular structural factors and running suture on IOP measurements obtained with both tonometers. RESULTS: IOP values obtained by DCT and GAT were strongly correlated in all eyes (r = .91; P < .001). DCT values measured 2.5 +/- 1.7 mm Hg higher than GAT readings (P < .001). A reduction of the mean IOP difference between DCT and GAT with an increase in IOP values (P < .001) was found. Regression analysis showed no effect of CCT, CC, astigmatism, and running suture on both DCT and GAT readings, either in DLKP or in PKP eyes. CONCLUSIONS: We found a good overall correlation between both tonometers but the agreement between instruments differs in high or low IOP ranges. The wide and varying 95% limits of agreement between DCT and GAT indicates that DCT provides IOP measurements on deep lamellar and penetrating keratoplasties which can be used in the clinical practice.

Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties

CERUTI, Piero
;
MORBIO, Roberta;MARCHINI, Giorgio
2008-01-01

Abstract

PURPOSE: To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes with corneal graft and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), and astigmatism on these methods. DESIGN: Prospective, observational cross-sectional study. METHODS: Eighteen eyes of 18 patients after penetrating keratoplasty (PKP) and 14 eyes of 14 patients after deep lamellar keratoplasty (DLKP) underwent IOP evaluation with DCT and GAT, and measurements of CCT, CC, and astigmatism. Bland-Altman plots were used to evaluate the agreement between tonometers. Multivariate regression analysis was used to evaluate the influence of ocular structural factors and running suture on IOP measurements obtained with both tonometers. RESULTS: IOP values obtained by DCT and GAT were strongly correlated in all eyes (r = .91; P < .001). DCT values measured 2.5 +/- 1.7 mm Hg higher than GAT readings (P < .001). A reduction of the mean IOP difference between DCT and GAT with an increase in IOP values (P < .001) was found. Regression analysis showed no effect of CCT, CC, astigmatism, and running suture on both DCT and GAT readings, either in DLKP or in PKP eyes. CONCLUSIONS: We found a good overall correlation between both tonometers but the agreement between instruments differs in high or low IOP ranges. The wide and varying 95% limits of agreement between DCT and GAT indicates that DCT provides IOP measurements on deep lamellar and penetrating keratoplasties which can be used in the clinical practice.
2008
IN-SITU KERATOMILEUSIS, INTRAOCULAR-PRESSURE MEASUREMENTS, CENTRAL CORNEAL THICKNESS, NORMAL-TENSION GLAUCOMA, PHOTOREFRACTIVE KERATECTOMY, OCULAR HYPERTENSION, LASIK, CURVATURE, EYES
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/315451
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 27
social impact