Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each re- ceived one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnifi- cation step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (mi- croscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.

Precision of Composite Restoration Removal When Using a Dental Operating Microscope for the First Time: An Exploratory Volumetric Study

Francesca Zotti;
2026-01-01

Abstract

Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each re- ceived one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnifi- cation step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (mi- croscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.
2026
dental operating microscope; magnification; composite restoration removal; precision direct restorations; novice operator; dental education; cone-beam computed tomography; intraoral scanning
File in questo prodotto:
File Dimensione Formato  
applsci-16-11644.pdf

accesso aperto

Tipologia: Versione dell'editore
Licenza: Creative commons
Dimensione 597.84 kB
Formato Adobe PDF
597.84 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1209907
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact