Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each re- ceived one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnifi- cation step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (mi- croscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.
Precision of Composite Restoration Removal When Using a Dental Operating Microscope for the First Time: An Exploratory Volumetric Study
Francesca Zotti;
2026-01-01
Abstract
Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each re- ceived one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnifi- cation step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (mi- croscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.| File | Dimensione | Formato | |
|---|---|---|---|
|
applsci-16-11644.pdf
accesso aperto
Tipologia:
Versione dell'editore
Licenza:
Creative commons
Dimensione
597.84 kB
Formato
Adobe PDF
|
597.84 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.