Objectives: Does the angulation of ultrashort implants influence the stability of the peri-implant bone? The present study aimed to evaluate the effectiveness of non-axial ultrashort implants after 2 to 9 years of follow-up in resorbed alveolar ridges. Materials and methods: All partially edentulous patients with ultrashort implants (< 6 mm) used in the posterior region of an atrophic mandible or maxilla, to support partial dentures in conjunction with standard implants, were included in this study. Peri-implant bone loss, success and survival rates, crestal bone levels, crown-to-implant ratio and implant angulation were measured for each implant. Implants were divided into two groups: straight implants with angulation < 17° (control group) and tilted implants with angulation > 17° (test group). Statistical analysis was used to find any significant differences between the two study groups and to investigate significant linear correlations among all the variables (p = 0.05). Results: A total of 42 ultrashort implants with a mean of 4 years of follow-up were included: 20 ultrashort axially loaded implants and 22 tilted implants. Mean crestal bone levels from baseline loading to maximum follow-up did not reveal statistical differences in regard to PBL; mean success and survival rates were 100% in all groups. Conclusions: PBL, success and survival rates of axial ultrashort implants and tilted ultrashort implants are comparable to those of conventional implants. Clinical relevance: This retrospective study revealed that ultrashort implants, even when placed with an angulation > 17°, can safely be used to support partial fixed prostheses. Further prospective clinical studies with larger samples and prospective design are needed to confirm these findings.
Analysis of ultra-short implants with different angulations: a retrospective case-control study with 2 to 9 years of follow-up
Malchiodi, Luciano;Zotti, Francesca;Nocini, Pier Francesco
2024-01-01
Abstract
Objectives: Does the angulation of ultrashort implants influence the stability of the peri-implant bone? The present study aimed to evaluate the effectiveness of non-axial ultrashort implants after 2 to 9 years of follow-up in resorbed alveolar ridges. Materials and methods: All partially edentulous patients with ultrashort implants (< 6 mm) used in the posterior region of an atrophic mandible or maxilla, to support partial dentures in conjunction with standard implants, were included in this study. Peri-implant bone loss, success and survival rates, crestal bone levels, crown-to-implant ratio and implant angulation were measured for each implant. Implants were divided into two groups: straight implants with angulation < 17° (control group) and tilted implants with angulation > 17° (test group). Statistical analysis was used to find any significant differences between the two study groups and to investigate significant linear correlations among all the variables (p = 0.05). Results: A total of 42 ultrashort implants with a mean of 4 years of follow-up were included: 20 ultrashort axially loaded implants and 22 tilted implants. Mean crestal bone levels from baseline loading to maximum follow-up did not reveal statistical differences in regard to PBL; mean success and survival rates were 100% in all groups. Conclusions: PBL, success and survival rates of axial ultrashort implants and tilted ultrashort implants are comparable to those of conventional implants. Clinical relevance: This retrospective study revealed that ultrashort implants, even when placed with an angulation > 17°, can safely be used to support partial fixed prostheses. Further prospective clinical studies with larger samples and prospective design are needed to confirm these findings.File | Dimensione | Formato | |
---|---|---|---|
2024_CLOI.pdf
solo utenti autorizzati
Tipologia:
Versione dell'editore
Licenza:
Copyright dell'editore
Dimensione
1.89 MB
Formato
Adobe PDF
|
1.89 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.