Computed tomography (CT)-guided percutaneous needle biopsy of the lung is a well-recognized and relatively safe diagnostic procedure for suspicious lung masses. Systemic air embolism (SAE) is a rare complication of transthoracic percutaneous lung biopsies. Herein, we present a case of an 81-year-old man who underwent CT-guided percutaneous needle biopsy of a suspicious nodule in the lower lobe of the right lung. Shortly after the procedure, the patient coughed up blood which prompted repeat CT imaging. He was found to have a massive cardiac air embolism. The patient became unresponsive and, despite resuscitation eforts, was pronounced dead. The pathophysiology, risk factors, clinical features, radiological evidence, and autopsy fndings associated with SAE are discussed, which may, in light of the current literature, assist with the dilemma between assessing procedural complications and medical liability. Given the instances of SAE in the setting of long operative procedures despite careful technical execution, providing accurate and in-depth information, including procedure-related risks, even the rarest but potentially fatal ones, is recommended for informed consent to reduce medicolegal litigation issues.
Fatal cardiac air embolism after CT-guided percutaneous needle lung biopsy: medical complication or medical malpractice?
Nicola Pigaiani
;Francesco Ausania;Federica Bortolotti;Matteo Brunelli;Domenico De Leo
2024-01-01
Abstract
Computed tomography (CT)-guided percutaneous needle biopsy of the lung is a well-recognized and relatively safe diagnostic procedure for suspicious lung masses. Systemic air embolism (SAE) is a rare complication of transthoracic percutaneous lung biopsies. Herein, we present a case of an 81-year-old man who underwent CT-guided percutaneous needle biopsy of a suspicious nodule in the lower lobe of the right lung. Shortly after the procedure, the patient coughed up blood which prompted repeat CT imaging. He was found to have a massive cardiac air embolism. The patient became unresponsive and, despite resuscitation eforts, was pronounced dead. The pathophysiology, risk factors, clinical features, radiological evidence, and autopsy fndings associated with SAE are discussed, which may, in light of the current literature, assist with the dilemma between assessing procedural complications and medical liability. Given the instances of SAE in the setting of long operative procedures despite careful technical execution, providing accurate and in-depth information, including procedure-related risks, even the rarest but potentially fatal ones, is recommended for informed consent to reduce medicolegal litigation issues.File | Dimensione | Formato | |
---|---|---|---|
s12024-023-00639-w (1).pdf
embargo fino al 15/09/2024
Licenza:
Accesso ristretto
Dimensione
1.72 MB
Formato
Adobe PDF
|
1.72 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.