The implantation of the PRESERFLO™ MicroShunt (PMS) device has been shown to significantly lower increased intraocular pressure (IOP) in patients with primary open-angle glaucoma (POAG). However, guidelines on best practice for patient selection and pre-/peri-/postoperative care management are lacking. The aim of this modified Delphi panel was to achieve expert consensus on the role of the PMS to treat patients with glaucoma in Europe.

Expert consensus on the use of the PRESERFLO™ microshunt device in the treatment of glaucoma: a modified Delphi panel

Marchini, Giorgio;
2022-01-01

Abstract

The implantation of the PRESERFLO™ MicroShunt (PMS) device has been shown to significantly lower increased intraocular pressure (IOP) in patients with primary open-angle glaucoma (POAG). However, guidelines on best practice for patient selection and pre-/peri-/postoperative care management are lacking. The aim of this modified Delphi panel was to achieve expert consensus on the role of the PMS to treat patients with glaucoma in Europe.
2022
Consensus
Delphi method
Europe
Glaucoma
MicroShunt
Open-angle glaucoma
PRESERFLO™
File in questo prodotto:
File Dimensione Formato  
s00415-022-11230-8.pdf

accesso aperto

Descrizione: CC BY 4.0 publisher version
Tipologia: Versione dell'editore
Licenza: Creative commons
Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1070689
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact