Nowadays Robotic assisted Minimally Invasive Surgeries (R-MIS) are the elective procedures for treating highly accurate and scarcely invasive pathologies, thanks to their abil- ity to empower surgeons’ dexterity and skills. The research on new Multi-Robots Surgery (MRS) platform is cardinal to the development of a new SARAS surgical robotic platform, which aims at carrying out autonomously the assistants tasks during R- MIS procedures. In this work, we will present the SARAS MRS platform validation protocol, framed in order to assess: (i) its technical performances in purely dexterity exercises, and (ii) its functional performances. The results obtained show a prototype able to put the users in the condition of accomplishing the tasks requested (both dexterity- and surgical-related), even with rea- sonably lower performances respect to the industrial standard. The main aspects on which further improvements are needed result to be the stability of the end effectors, the depth per- ception and the vision systems, to be enriched with dedicated virtual fixtures. The SARAS’ aim is to reduce the main surgeon’s workload through the automation of assistive tasks which would benefit both surgeons and patients by facilitating the surgery and reducing the operation time.

Technical and Functional Validation of a Teleoperated Multirobots Platform for Minimally Invasive Surgery

Siracusano, Salvatore;Falezza, Fabio;Setti, Francesco;Muradore, Riccardo
2020-01-01

Abstract

Nowadays Robotic assisted Minimally Invasive Surgeries (R-MIS) are the elective procedures for treating highly accurate and scarcely invasive pathologies, thanks to their abil- ity to empower surgeons’ dexterity and skills. The research on new Multi-Robots Surgery (MRS) platform is cardinal to the development of a new SARAS surgical robotic platform, which aims at carrying out autonomously the assistants tasks during R- MIS procedures. In this work, we will present the SARAS MRS platform validation protocol, framed in order to assess: (i) its technical performances in purely dexterity exercises, and (ii) its functional performances. The results obtained show a prototype able to put the users in the condition of accomplishing the tasks requested (both dexterity- and surgical-related), even with rea- sonably lower performances respect to the industrial standard. The main aspects on which further improvements are needed result to be the stability of the end effectors, the depth per- ception and the vision systems, to be enriched with dedicated virtual fixtures. The SARAS’ aim is to reduce the main surgeon’s workload through the automation of assistive tasks which would benefit both surgeons and patients by facilitating the surgery and reducing the operation time.
2020
Validation protocol, tele-operated surgical robotic system, robotic end effector task metrics, functional evaluation, surgical-related tasks
File in questo prodotto:
File Dimensione Formato  
09078032.pdf

accesso aperto

Tipologia: Versione dell'editore
Licenza: Dominio pubblico
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1021924
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact