Rapid detection of Methicillin Resistant Staphylococcus aureus (MRSA) is an important concern for both treatment and implementation of infection control policies. The present study provides an ‘in house’ real-time PCR assay to detect directly nuc, pvl, and mecA genes. The assay is able to perform identification of MRSA, Methicillin-Sensitive S. aureus, Methicillin-Resistant Coagulase Negative Staphylococci and the Panton-Valentine leukocidin virulence gene from rectal and pharyngeal swab samples in a screening context. We found an analytical sensitivity of this current Triplex PCR assay of 514 CFU/mL. Analytical specificity was tested with different Gram-positive and Gram-negative species and yielded no false-positive PCR signal. The sensitivity and specificity of the Triplex Real Time PCR were both 100% for these targets when compared with the culture and conventional methods. This assay is readily adaptable for routine use in a microbiology laboratory, as it will enable the implementation of timely and properly guided therapy and infection control strategies.
Real-time PCR assay for detection of Staphylococcus aureus, Panton-Valentine Leucocidin and Methicillin Resistance directly from clinical samples
Galia, Liliana;Ligozzi, Marco;Bertoncelli, Anna;Mazzariol, Annarita
2019-01-01
Abstract
Rapid detection of Methicillin Resistant Staphylococcus aureus (MRSA) is an important concern for both treatment and implementation of infection control policies. The present study provides an ‘in house’ real-time PCR assay to detect directly nuc, pvl, and mecA genes. The assay is able to perform identification of MRSA, Methicillin-Sensitive S. aureus, Methicillin-Resistant Coagulase Negative Staphylococci and the Panton-Valentine leukocidin virulence gene from rectal and pharyngeal swab samples in a screening context. We found an analytical sensitivity of this current Triplex PCR assay of 514 CFU/mL. Analytical specificity was tested with different Gram-positive and Gram-negative species and yielded no false-positive PCR signal. The sensitivity and specificity of the Triplex Real Time PCR were both 100% for these targets when compared with the culture and conventional methods. This assay is readily adaptable for routine use in a microbiology laboratory, as it will enable the implementation of timely and properly guided therapy and infection control strategies.File | Dimensione | Formato | |
---|---|---|---|
Real time PCR assay for detection.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Altro materiale allegato
Licenza:
Creative commons
Dimensione
579.58 kB
Formato
Adobe PDF
|
579.58 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.