Long-acting glucagon-like peptide 1 receptor agonists are increasingly used to treat type 2 diabetes. An increase of heart rate (HR) has been observed with their use. To elucidate the role of the cardiac sympatho-vagal balance as a possible mediator of the reported increase in HR, we performed power spectral analysis of HR variability (HRV) in patients receiving exenatide extended-release (ER). Twenty-eight ambulatory patients with type 2 diabetes underwent evaluation at initiation of exenatide-ER and thereafter at 3 and at 6 months. To obtain spectral analyses of HRV, a computerized acquisition of 10 minutes of RR electrocardiogram intervals (mean values of ~700 RR intervals) were recorded both in lying and in standing positions. All patients showed a substantial increase of HR both in lying and in standing positions. Systolic blood pressure, body weight, and glycated hemoglobin A1c significantly decreased both at 3 and 6 months compared with basal levels. The low-frequency/high-frequency ratio varied from 3.05 ± 0.4 to 1.64 ± 0.2 (P < 0.001) after 3 months and to 1.57 ± 0.3 (P < 0.001) after 6 months in a lying position and from 4.56 ± 0.8 to 2.24 ± 0.3 (P < 0.001) after 3 months and to 2.38 ± 0.4 (P < 0.001) after 6 months in a standing position compared with basal values, respectively. HR variations, induced by exenatide-ER treatment, do not appear to be related to sympathetic autonomic tone. Of note, we observed a relative increase of vagal influence on the heart.

Long-Acting GLP-1 Receptor Agonist Exenatide Influence on the Autonomic Cardiac Sympatho-Vagal Balance

Cacciatori, Vittorio;Zoppini, Giacomo;Pichiri, Isabella;Trombetta, Maddalena;Targher, Giovanni;Santi, Lorenza;Bonora, Enzo
2017-01-01

Abstract

Long-acting glucagon-like peptide 1 receptor agonists are increasingly used to treat type 2 diabetes. An increase of heart rate (HR) has been observed with their use. To elucidate the role of the cardiac sympatho-vagal balance as a possible mediator of the reported increase in HR, we performed power spectral analysis of HR variability (HRV) in patients receiving exenatide extended-release (ER). Twenty-eight ambulatory patients with type 2 diabetes underwent evaluation at initiation of exenatide-ER and thereafter at 3 and at 6 months. To obtain spectral analyses of HRV, a computerized acquisition of 10 minutes of RR electrocardiogram intervals (mean values of ~700 RR intervals) were recorded both in lying and in standing positions. All patients showed a substantial increase of HR both in lying and in standing positions. Systolic blood pressure, body weight, and glycated hemoglobin A1c significantly decreased both at 3 and 6 months compared with basal levels. The low-frequency/high-frequency ratio varied from 3.05 ± 0.4 to 1.64 ± 0.2 (P < 0.001) after 3 months and to 1.57 ± 0.3 (P < 0.001) after 6 months in a lying position and from 4.56 ± 0.8 to 2.24 ± 0.3 (P < 0.001) after 3 months and to 2.38 ± 0.4 (P < 0.001) after 6 months in a standing position compared with basal values, respectively. HR variations, induced by exenatide-ER treatment, do not appear to be related to sympathetic autonomic tone. Of note, we observed a relative increase of vagal influence on the heart.
2017
autonomic nervous system, GLP-1 receptor agonist, power spectral analysis
File in questo prodotto:
File Dimensione Formato  
js.2017-00300-2.pdf

Open Access dal 01/12/2018

Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 790.29 kB
Formato Adobe PDF
790.29 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/971858
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact