Patient-specific finite element (FE) models can assess the impact of mitral valve (MV) repair on the complex MV anatomy and function. However, FE excessive time requirements hamper their use for surgical planning; mass-spring models (MSMs) represent a more approximate approach but can provide almost real-time simulations. On this basis, we implemented MSMs of three healthy MVs from cardiac magnetic resonance (cMR) imaging to simulate the systolic MV closure, including the in vivo papillary muscles and annular kinematics, and the anisotropic and non-linear mechanical response of MV tissues. To test MSM reliability we compared the systolic peak configurations computed by MSMs and FE: mismatches by less than twice the in-plane cMR image resolution were detected over 75% of the leaflets' surface, independently of the MSM mesh refinement and of the specific MV anatomy. Data on MSMs time-efficiency and data from the comparison of MSMs vs. FE models suggest that MSM could represent a suitable trade-off between almost real-time simulations and reliability when computing MV systolic configuration, with the potential to be used in a clinical setting either as a support to the decisional process or as a virtual training tool.

Mass-spring models for the simulation of mitral valve function: Looking for a trade-off between reliability and time-efficiency

Sturla, Francesco;ONORATI, FRANCESCO;PUPPINI, Giovanni;SELMI, MATTEO;LUCIANI, GIOVANNI BATTISTA;FAGGIAN, Giuseppe;REDAELLI, ANDREA;
2017-01-01

Abstract

Patient-specific finite element (FE) models can assess the impact of mitral valve (MV) repair on the complex MV anatomy and function. However, FE excessive time requirements hamper their use for surgical planning; mass-spring models (MSMs) represent a more approximate approach but can provide almost real-time simulations. On this basis, we implemented MSMs of three healthy MVs from cardiac magnetic resonance (cMR) imaging to simulate the systolic MV closure, including the in vivo papillary muscles and annular kinematics, and the anisotropic and non-linear mechanical response of MV tissues. To test MSM reliability we compared the systolic peak configurations computed by MSMs and FE: mismatches by less than twice the in-plane cMR image resolution were detected over 75% of the leaflets' surface, independently of the MSM mesh refinement and of the specific MV anatomy. Data on MSMs time-efficiency and data from the comparison of MSMs vs. FE models suggest that MSM could represent a suitable trade-off between almost real-time simulations and reliability when computing MV systolic configuration, with the potential to be used in a clinical setting either as a support to the decisional process or as a virtual training tool.
2017
Computational modeling, Finite element model, Heart valve repair, Mass-spring model, Mitral valve
File in questo prodotto:
File Dimensione Formato  
2017_Mass_spring_model_FEMmitral_MedEng&Physics.pdf

non disponibili

Tipologia: Versione dell'editore
Licenza: Accesso ristretto
Dimensione 3.96 MB
Formato Adobe PDF
3.96 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/969176
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 7
social impact