BACKGROUND AND PURPOSE Transorbital sonography (TOS) is a promising tool to support the clinical diagnosis of optic neuritis (ON) by showing thickening of optic nerve. In this study, we aimed to define its specific role in follow-up of ON patients. METHODS We measured ultrasonography parameters and visual acuity (VA) at presentation and after 1 year in 45 patients with newly diagnosed ON. Two vascular sonographers used B-mode TOS to evaluate mean optic nerve diameter (OND) and optic nerve sheath diameter (ONSD). RESULTS Median ONSD values were significantly thicker in patients with ON in the affected eye (6.4 mm, interquartile range [IQR]: 6.0-6.9) at presentation compared with the nonaffected side (5.7 mm; IQR: 5.2-6.1) (P < .001). The median OND was not significantly thicker at presentation in the affected eye (3.0 mm; IQR: 2.9-3.4) compared with the fellow eye (2.9 mm; IQR: 2.8-3.2) (P = .09). Logarithmic VA was significantly compromised at presentation in the affected eye (.16; IQR: .00–.55) compared with fellow eye (.00; IQR: .00–.00) (P < .001). After 1 year, no significant difference (P ≥ .05) was found between ONSD or OND of the affected side compared with the nonaffected side. VA improved in most of the patients but remained significantly impaired in affected eye after 1 year. CONCLUSIONS TOS is a useful tool to support diagnosis of ON. This technique seems to have less value to evaluate atrophy of the optic nerve after 12 months.

Transorbital sonography and visual outcome for the diagnosis and monitoring of optic neuritis

BRIGO, Francesco
2017-01-01

Abstract

BACKGROUND AND PURPOSE Transorbital sonography (TOS) is a promising tool to support the clinical diagnosis of optic neuritis (ON) by showing thickening of optic nerve. In this study, we aimed to define its specific role in follow-up of ON patients. METHODS We measured ultrasonography parameters and visual acuity (VA) at presentation and after 1 year in 45 patients with newly diagnosed ON. Two vascular sonographers used B-mode TOS to evaluate mean optic nerve diameter (OND) and optic nerve sheath diameter (ONSD). RESULTS Median ONSD values were significantly thicker in patients with ON in the affected eye (6.4 mm, interquartile range [IQR]: 6.0-6.9) at presentation compared with the nonaffected side (5.7 mm; IQR: 5.2-6.1) (P < .001). The median OND was not significantly thicker at presentation in the affected eye (3.0 mm; IQR: 2.9-3.4) compared with the fellow eye (2.9 mm; IQR: 2.8-3.2) (P = .09). Logarithmic VA was significantly compromised at presentation in the affected eye (.16; IQR: .00–.55) compared with fellow eye (.00; IQR: .00–.00) (P < .001). After 1 year, no significant difference (P ≥ .05) was found between ONSD or OND of the affected side compared with the nonaffected side. VA improved in most of the patients but remained significantly impaired in affected eye after 1 year. CONCLUSIONS TOS is a useful tool to support diagnosis of ON. This technique seems to have less value to evaluate atrophy of the optic nerve after 12 months.
2017
optic nerve sheath diameter; optic disc elevation; optic nerve diameter; optic neuritis; transorbital sonography; visual acuity
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/960396
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact