Most of the immunoassays workload is processed in clinical laboratories within a time span comparable to the clinical chemistry and the haematology assays and the analytical work is usually completed between 1:00 and 2:00 p.m. In order to accelerate the auto-verification of the results of tumour markers (Total and free PSA, CEA, CA 125, CA 15-3, CA 19-9, TPA, AFP, NSE, S 100 protein), and hormones (TSH, FT4, FT3, Prolactin, total testosterone) and Procalcitonin (PCT) we used DNSevTM expert system implementing 13 rules based on decision levels/reference intervals and reference change values. The auto-verification procedure has been implemented after a 6-month trial in June 2004 and in 2005 the immunoassays section supervisor was able to verify about 500 results in about 30 min 5 days/week. We conclude that the auto-verification of immunoassays implemented in our laboratory is fast and consistent among different supervisors and leaves more time for an effective and timely interaction with clinicians and general practitioners

The DNSev™ expert system in the auto-verification of tumour markers and hormones results

CARUSO, BEATRICE;
2006-01-01

Abstract

Most of the immunoassays workload is processed in clinical laboratories within a time span comparable to the clinical chemistry and the haematology assays and the analytical work is usually completed between 1:00 and 2:00 p.m. In order to accelerate the auto-verification of the results of tumour markers (Total and free PSA, CEA, CA 125, CA 15-3, CA 19-9, TPA, AFP, NSE, S 100 protein), and hormones (TSH, FT4, FT3, Prolactin, total testosterone) and Procalcitonin (PCT) we used DNSevTM expert system implementing 13 rules based on decision levels/reference intervals and reference change values. The auto-verification procedure has been implemented after a 6-month trial in June 2004 and in 2005 the immunoassays section supervisor was able to verify about 500 results in about 30 min 5 days/week. We conclude that the auto-verification of immunoassays implemented in our laboratory is fast and consistent among different supervisors and leaves more time for an effective and timely interaction with clinicians and general practitioners
2006
Auto-validation; Auto-verification; Hormones; Reference change value; Tumour markers
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/959655
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact