The use of optical methods for the detection of radionuclides is becoming an established tool for preclinical molecular imaging experiments. In this paper we present a set of proof of principle experiments showing that planar bremsstrahlung radiation images can be detected with an intensifying screen using a small animal optical imager based on charge coupled device detector. We develop a bremsstrahlung source using a (32)P-ATP vial placed in a Plexiglas box, the source with an intensifying screen on top was placed inside a small animal optical imaging system. Bremsstrahlung radiation images were produced with the (32)P-ATP source only and also with a pair of pliers placed between the source and the screen. We found that the pair of pliers absorption image matches the shape of the object. Spatial resolution measurements were not performed however, the bremsstrahlung image of the pliers show that the resolution is relatively poor due to a large penumbra effect. We conclude that it is possible to produce planar bremsstrahlung images using optical imaging devices.

Bremsstrahlung radiation detection for small animal imaging using a CCD detector

BOSCHI, Federico
2016-01-01

Abstract

The use of optical methods for the detection of radionuclides is becoming an established tool for preclinical molecular imaging experiments. In this paper we present a set of proof of principle experiments showing that planar bremsstrahlung radiation images can be detected with an intensifying screen using a small animal optical imager based on charge coupled device detector. We develop a bremsstrahlung source using a (32)P-ATP vial placed in a Plexiglas box, the source with an intensifying screen on top was placed inside a small animal optical imaging system. Bremsstrahlung radiation images were produced with the (32)P-ATP source only and also with a pair of pliers placed between the source and the screen. We found that the pair of pliers absorption image matches the shape of the object. Spatial resolution measurements were not performed however, the bremsstrahlung image of the pliers show that the resolution is relatively poor due to a large penumbra effect. We conclude that it is possible to produce planar bremsstrahlung images using optical imaging devices.
2016
Bremsstrahlung radiation; optical imaging; small animal imaging
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/948376
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact