A major challenge in high-resolution intravital confocal and multiphoton microscopy is physiologic tissue movement during image acquisition. Of the various physiological sources of movement, respiration has arguably the largest and most wide-ranging effect. We describe a technique for achieving stabilized microscopy imaging using a dual strategy. First, we designed a mechanical stabilizer for constraining physical motion; this served to simultaneously increase the in-focus range over which data can be acquired as well as increase the reproducibility of imaging a certain position within each confocal imaging plane. Second, by implementing a retrospective breathing-gated imaging modality, we performed selective image extraction gated to a particular phase of the respiratory cycle. Thanks to the high reproducibility in position, all gated images presented a high degree of correlation over time. The images obtained using this technique not only showed significant improvements over images acquired without the stabilizer, but also demonstrated accurate in vivo imaging during longitudinal studies. The described methodology is easy to implement with any commercial imaging system, as are used by most biological imaging laboratories, and can be used for both confocal and multiphoton laser scanning microscopy.

Improved intravital microscopy via synchronization of respiration and holder stabilization

FUMENE FERUGLIO, Paolo;
2012-01-01

Abstract

A major challenge in high-resolution intravital confocal and multiphoton microscopy is physiologic tissue movement during image acquisition. Of the various physiological sources of movement, respiration has arguably the largest and most wide-ranging effect. We describe a technique for achieving stabilized microscopy imaging using a dual strategy. First, we designed a mechanical stabilizer for constraining physical motion; this served to simultaneously increase the in-focus range over which data can be acquired as well as increase the reproducibility of imaging a certain position within each confocal imaging plane. Second, by implementing a retrospective breathing-gated imaging modality, we performed selective image extraction gated to a particular phase of the respiratory cycle. Thanks to the high reproducibility in position, all gated images presented a high degree of correlation over time. The images obtained using this technique not only showed significant improvements over images acquired without the stabilizer, but also demonstrated accurate in vivo imaging during longitudinal studies. The described methodology is easy to implement with any commercial imaging system, as are used by most biological imaging laboratories, and can be used for both confocal and multiphoton laser scanning microscopy.
2012
Computer-Aided Design; Equipment Design; Equipment Failure Analysis; Image Enhancement; Immobilization; Microscopy, Confocal; Microscopy, Fluorescence, Multiphoton; Reproducibility of Results; Respiratory-Gated Imaging Techniques; Sensitivity and Specificity; Subtraction Technique
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/947945
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact