Bicuspid aortic valve (BAV) is associated with aortic dilatation and aneurysm. Several studies evidenced an eccentric systolic flow in ascending aorta associated with increased wall shear stresses (WSS) and the occurrence of an helical systolic flow. This study seeks to elucidate the connections between jet asymmetry and helical flow in patients with normally functioning BAV and dilated ascending aorta. We performed a computational parametric study by varying, for a patient-specific geometry, the valve area and the flow rate entering the aorta and drawing also a tricuspid valve (TAV). We considered also phase-contrast magnetic resonance imaging of four BAV and TAV patients. Measurement of normalized flow asymmetry index, systolic WSS and of a new index (positive helix fraction, PHF) quantifying the presence of a single a single helical flow were performed. In our computation, BAV cases featured higher values of all indices with respect to TAV in both numerical and imaged-based results. Moreover, all indices increased with decreasing valve area and/or with increasing flow rate. This allowed to separate the BAV and TAV cases with respect to the jet asymmetry, WSS localization and helical flow. Interestingly, these results were obtained without modeling the leaflets.

Helical flows and asymmetry of blood jet in dilated ascending aorta with normally functioning bicuspid valve.

LUCIANI, GIOVANNI BATTISTA;
2013-01-01

Abstract

Bicuspid aortic valve (BAV) is associated with aortic dilatation and aneurysm. Several studies evidenced an eccentric systolic flow in ascending aorta associated with increased wall shear stresses (WSS) and the occurrence of an helical systolic flow. This study seeks to elucidate the connections between jet asymmetry and helical flow in patients with normally functioning BAV and dilated ascending aorta. We performed a computational parametric study by varying, for a patient-specific geometry, the valve area and the flow rate entering the aorta and drawing also a tricuspid valve (TAV). We considered also phase-contrast magnetic resonance imaging of four BAV and TAV patients. Measurement of normalized flow asymmetry index, systolic WSS and of a new index (positive helix fraction, PHF) quantifying the presence of a single a single helical flow were performed. In our computation, BAV cases featured higher values of all indices with respect to TAV in both numerical and imaged-based results. Moreover, all indices increased with decreasing valve area and/or with increasing flow rate. This allowed to separate the BAV and TAV cases with respect to the jet asymmetry, WSS localization and helical flow. Interestingly, these results were obtained without modeling the leaflets.
2013
bicuspid aortic valve, aortic, ANEURYSM, computation, Aortic Root, Magnetic Resonance Imaging, Ross Operation, Pulmonary Autograft, Bicuspid Aortic Valve, Congenital Heart Disease, Yacoub Operation, Valve Repair, Valve Sparing Operation, Computational Fluid Dynamics
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10237-012-0444-1.pdf

solo utenti autorizzati

Descrizione: articolo principale
Tipologia: Documento in Post-print
Licenza: Accesso ristretto
Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/762767
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 46
social impact