Scintigraphy with [111In-DTPA-D-Phe]-octreotide is a recently developed technique for imaging somatostatin receptors in many neuroendocrine tumors. A good correlation between high [111In-DTPA-D-Phe]-octreotide uptake and the response to octreotide therapy has been proved in TSH- and GH-secreting pituitary adenomas, while few and conflicting scintigraphic data on somatostatin receptors in non-functioning tumors have been reported in the literature. The present study presents the results obtained with [111In-DTPA-D-Phe]-octreotide scintigraphy in thirteen patients with GH-secreting pituitary adenoma, four patients with inappropriate TSH-secretion and twelve patients with non-functioning pituitary adenoma. Twelve out of the 13 patients with GH-secreting pituitary adenomas had a positive scan; moreover, in 5/6 patients with a GH-secreting microadenoma (tumor size range 5-8 mm) a positive scan was found. Two TSH-secreting macroadenomas had a positive scan while a negative scan was obtained for a TSH-secreting pituitary microadenoma and in a patient with non-neoplastic, inappropriate secretion of TSH. Finally, only 2/12 patients with non-functioning pituitary adenoma showed a positive scan. In conclusion, [111In-DTPA-D-Phe]-octreotide scintigraphy is a useful tool to confirm the presence of somatostatin receptors in selected patients with GH- and TSH-secreting pituitary adenoma. The role of [111In-DTPA-D-Phe]-octreotide scintigraphy in non-functioning pituitary tumors remains to be established, but it could be useful for octreotide treatment in patients who refuse surgery or who are poor surgical candidates.
[111In-DTPA-D-Phe]-octreotide scintigraphy in functioning and non-functioning pituitary adenomas
FERDEGHINI, Marco;
1995-01-01
Abstract
Scintigraphy with [111In-DTPA-D-Phe]-octreotide is a recently developed technique for imaging somatostatin receptors in many neuroendocrine tumors. A good correlation between high [111In-DTPA-D-Phe]-octreotide uptake and the response to octreotide therapy has been proved in TSH- and GH-secreting pituitary adenomas, while few and conflicting scintigraphic data on somatostatin receptors in non-functioning tumors have been reported in the literature. The present study presents the results obtained with [111In-DTPA-D-Phe]-octreotide scintigraphy in thirteen patients with GH-secreting pituitary adenoma, four patients with inappropriate TSH-secretion and twelve patients with non-functioning pituitary adenoma. Twelve out of the 13 patients with GH-secreting pituitary adenomas had a positive scan; moreover, in 5/6 patients with a GH-secreting microadenoma (tumor size range 5-8 mm) a positive scan was found. Two TSH-secreting macroadenomas had a positive scan while a negative scan was obtained for a TSH-secreting pituitary microadenoma and in a patient with non-neoplastic, inappropriate secretion of TSH. Finally, only 2/12 patients with non-functioning pituitary adenoma showed a positive scan. In conclusion, [111In-DTPA-D-Phe]-octreotide scintigraphy is a useful tool to confirm the presence of somatostatin receptors in selected patients with GH- and TSH-secreting pituitary adenoma. The role of [111In-DTPA-D-Phe]-octreotide scintigraphy in non-functioning pituitary tumors remains to be established, but it could be useful for octreotide treatment in patients who refuse surgery or who are poor surgical candidates.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.