To analyse the clinical outcome at 4 years in patients with coronary artery disease treated with bare metal stents (BMS) vs. BMS and oral prednisone, or drug-eluting stents (DES), all assuming similar adjunctive medical treatment.Five Italian hospitals enrolled 375 non-diabetic, ischaemic patients without contraindications to dual anti-platelet treatment or corticosteroid therapy in a randomized controlled study. The primary endpoint was the event-free survival of cardiovascular death, myocardial infarction, and recurrence of ischaemia needing repeated target vessel revascularization at 1 year, and this was significantly lower in the BMS group (80.8\%) compared with the prednisone (88.0\%) and DES group (88.8\%, P = 0.04 and 0.006, respectively). The long-term analysis of the primary endpoint was a pre-specified aim of the trial, and was performed at 1447 days (median, IQ range = 1210-1641). Patients receiving BMS alone had significantly lower event-free survival (75.3\%) compared with 84.1\% in the prednisone group (HR: 0.447; 95\% CI: 0.25-0.80, P = 0.007) and 80.6\% in DES patients (HR: 0.519; 95\% CI: 0.29-0.93, P = 0.03). Prednisone-treated patients did not develop new treatment-related clinical problems. Drug-eluting stents patients suffered more very late stent thrombosis as a cause of spontaneous myocardial infarction. The need for target vessel revascularization remained lower in the prednisone and DES groups (13.6 and 15.2\%, respectively), compared with BMS (23.2\%).The clinical benefits of prednisone compared with BMS only persisted almost unchanged at 4 years. Drug-eluting stents performed better than BMS at long-term, although the advantages observed at 1 year were in part attenuated because of the occurrence of very late stent thrombosis and late revascularizations. Clinical Trial NCT 00369356.
Titolo: | Long-term clinical follow-up of the multicentre, randomized study to test immunosuppressive therapy with oral prednisone for the prevention of restenosis after percutaneous coronary interventions: Cortisone plus BMS or DES veRsus BMS alone to EliminAte Restenosis (CEREA-DES). | |
Autori: | ||
Data di pubblicazione: | 2013 | |
Rivista: | ||
Abstract: | To analyse the clinical outcome at 4 years in patients with coronary artery disease treated with bare metal stents (BMS) vs. BMS and oral prednisone, or drug-eluting stents (DES), all assuming similar adjunctive medical treatment.Five Italian hospitals enrolled 375 non-diabetic, ischaemic patients without contraindications to dual anti-platelet treatment or corticosteroid therapy in a randomized controlled study. The primary endpoint was the event-free survival of cardiovascular death, myocardial infarction, and recurrence of ischaemia needing repeated target vessel revascularization at 1 year, and this was significantly lower in the BMS group (80.8\%) compared with the prednisone (88.0\%) and DES group (88.8\%, P = 0.04 and 0.006, respectively). The long-term analysis of the primary endpoint was a pre-specified aim of the trial, and was performed at 1447 days (median, IQ range = 1210-1641). Patients receiving BMS alone had significantly lower event-free survival (75.3\%) compared with 84.1\% in the prednisone group (HR: 0.447; 95\% CI: 0.25-0.80, P = 0.007) and 80.6\% in DES patients (HR: 0.519; 95\% CI: 0.29-0.93, P = 0.03). Prednisone-treated patients did not develop new treatment-related clinical problems. Drug-eluting stents patients suffered more very late stent thrombosis as a cause of spontaneous myocardial infarction. The need for target vessel revascularization remained lower in the prednisone and DES groups (13.6 and 15.2\%, respectively), compared with BMS (23.2\%).The clinical benefits of prednisone compared with BMS only persisted almost unchanged at 4 years. Drug-eluting stents performed better than BMS at long-term, although the advantages observed at 1 year were in part attenuated because of the occurrence of very late stent thrombosis and late revascularizations. Clinical Trial NCT 00369356. | |
Handle: | http://hdl.handle.net/11562/631172 | |
Appare nelle tipologie: | 01.01 Articolo in Rivista |