The validation process is essential in accredited laboratory medicine, but is rarely regarded as an issue in the preanalytical management. The aim of this study was to validate five kinds of lithium heparin vacuum tubes for routine clinical chemistry laboratory testing. Blood specimens from 100 volunteers in five different plasma vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: PST® and Tube V: PST II®) were collected by a single expert phlebotomist. The routine clinical chemistry tests were performed on a Cobas® 6000 <c501> module. The significance of the differences between samples was statistically assessed at p < 0.005. The biases from the different tubes were compared with the current desirable quality specifications. Basically, significant differences could be confirmed by RM ANOVA for the results of the clinical chemistry tests on the following components: glucose, urea, creatinine, alkaline phosphatase, amylase, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, total bilirubin, phosphate, Ca, Mg, Fe and K. Clinically significant variations as compared with the current desirable quality specifications were found for glucose, creatinine, amylase, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, Ca, Mg and K. In conclusion, our results do not support arbitrary interchange among brands of plasma vacuum tubes. Future investigations are needed to understand the reasons of these observations; in the meantime, we suggest that laboratory managers standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.

Quality management of preanalytical phase: Impact of lithium heparin vacuum tubes changes on clinical chemistry tests

De Souza Lima Oliveira, Gabriel;SALVAGNO, GIAN LUCA;LIPPI, Giuseppe;MONTAGNANA, Martina;GUIDI, Giancesare
2013-01-01

Abstract

The validation process is essential in accredited laboratory medicine, but is rarely regarded as an issue in the preanalytical management. The aim of this study was to validate five kinds of lithium heparin vacuum tubes for routine clinical chemistry laboratory testing. Blood specimens from 100 volunteers in five different plasma vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: PST® and Tube V: PST II®) were collected by a single expert phlebotomist. The routine clinical chemistry tests were performed on a Cobas® 6000 module. The significance of the differences between samples was statistically assessed at p < 0.005. The biases from the different tubes were compared with the current desirable quality specifications. Basically, significant differences could be confirmed by RM ANOVA for the results of the clinical chemistry tests on the following components: glucose, urea, creatinine, alkaline phosphatase, amylase, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, total bilirubin, phosphate, Ca, Mg, Fe and K. Clinically significant variations as compared with the current desirable quality specifications were found for glucose, creatinine, amylase, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, Ca, Mg and K. In conclusion, our results do not support arbitrary interchange among brands of plasma vacuum tubes. Future investigations are needed to understand the reasons of these observations; in the meantime, we suggest that laboratory managers standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.
2013
diagnostic; tubes; validation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/620556
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact