PURPOSE: To evaluate the clinical impact of intraoperative ultrasound (IOUS) in the detection of liver metastases during the years, as compared with those of other imaging modalities. MATERIALS AND METHODS: All IOUS scans performed for detection of liver metastases from 2000 to 2006 were retrospectively reviewed and compared with the results of preoperative imaging modalities: Ultrasound (US), Computed Tomography (CT), and/or Magnetic Resonance (MR). The number of cases in which IOUS and preoperative imaging studies produced discordant results, in terms of presence/absence of focal liver lesions, was calculated per year. Statistical analysis was performed using the McNemar test. A p value < 0.05 was considered statistically significant. RESULTS: Eighty-three IOUS scans performed in 2000-2003 were reviewed, and discordance with preoperative imaging findings was found in 19/83 (23%) cases. Of the 42 IOUS scans done during the 2004-2006 period, 10/42 (24%) showed discordance with preoperative studies. All metastases diagnosed with imaging studies were pathologically confirmed. The number of discordant cases in the two periods were not significantly different (p = 0.2). CONCLUSION: IOUS is still useful in the detection of liver metastases. Its decreased use is probably due to the improved accuracy of preoperative imaging modalities.
Titolo: | Is intraoperative ultrasound (IOUS) still useful for the detection of liver metastases? | |
Autori: | ||
Data di pubblicazione: | 2009 | |
Rivista: | ||
Abstract: | PURPOSE: To evaluate the clinical impact of intraoperative ultrasound (IOUS) in the detection of liver metastases during the years, as compared with those of other imaging modalities. MATERIALS AND METHODS: All IOUS scans performed for detection of liver metastases from 2000 to 2006 were retrospectively reviewed and compared with the results of preoperative imaging modalities: Ultrasound (US), Computed Tomography (CT), and/or Magnetic Resonance (MR). The number of cases in which IOUS and preoperative imaging studies produced discordant results, in terms of presence/absence of focal liver lesions, was calculated per year. Statistical analysis was performed using the McNemar test. A p value < 0.05 was considered statistically significant. RESULTS: Eighty-three IOUS scans performed in 2000-2003 were reviewed, and discordance with preoperative imaging findings was found in 19/83 (23%) cases. Of the 42 IOUS scans done during the 2004-2006 period, 10/42 (24%) showed discordance with preoperative studies. All metastases diagnosed with imaging studies were pathologically confirmed. The number of discordant cases in the two periods were not significantly different (p = 0.2). CONCLUSION: IOUS is still useful in the detection of liver metastases. Its decreased use is probably due to the improved accuracy of preoperative imaging modalities. | |
Handle: | http://hdl.handle.net/11562/515151 | |
Appare nelle tipologie: | 01.01 Articolo in Rivista |