We tested 145 clinical isolates in an attempt to evaluate some of the most widely used commercial identification systems in Europe in terms of their ability to identify Providencia strains. Two manual miniaturized systems (API 20E and Enterotube II) and three mechanized-automated systems (Cobas-Bact, Sceptor System, and Titertek-Enterobac-Rapid Automated System) were evaluated. Providencia alcalifaciens and Providencia rettgeri strains were correctly identified by all systems in all cases, and in most cases identification was achieved without the aid of supplementary tube tests. By contrast, Providencia stuartii was identified without the aid of supplementary tube tests for only 42.5% (API 20E), 37.5% (Enterotube), 68.7% (Sceptor), and 71.2% (Cobas-Bact) of the isolates. The overall misidentification rates were 16.3, 11.3, 11.3, and 10%, respectively. The Titertek-Enterobac-Rapid Automated System failed to identify only 1 of 80 strains (1.3%) and required supplementary tests in 2 other cases (2.5%). Since

Commercial identification systems often fail to identify Providencia stuartii

CORNAGLIA, Giuseppe;
1988-01-01

Abstract

We tested 145 clinical isolates in an attempt to evaluate some of the most widely used commercial identification systems in Europe in terms of their ability to identify Providencia strains. Two manual miniaturized systems (API 20E and Enterotube II) and three mechanized-automated systems (Cobas-Bact, Sceptor System, and Titertek-Enterobac-Rapid Automated System) were evaluated. Providencia alcalifaciens and Providencia rettgeri strains were correctly identified by all systems in all cases, and in most cases identification was achieved without the aid of supplementary tube tests. By contrast, Providencia stuartii was identified without the aid of supplementary tube tests for only 42.5% (API 20E), 37.5% (Enterotube), 68.7% (Sceptor), and 71.2% (Cobas-Bact) of the isolates. The overall misidentification rates were 16.3, 11.3, 11.3, and 10%, respectively. The Titertek-Enterobac-Rapid Automated System failed to identify only 1 of 80 strains (1.3%) and required supplementary tests in 2 other cases (2.5%). Since
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/5042
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 8
social impact