OBJECTIVE: Bioimpedance analysis (BIA) is a potential field and clinical method for evaluating skeletal muscle mass (SM) and %fat. A new BIA system has 8-(two on each hand and foot) rather than 4-contact electrodes allowing for rapid 'whole-body' and regional body composition evaluation. DESIGN: This study evaluated the 50 kHz BC-418 8-contact electrode and TBF-310 4-contact electrode foot-foot BIA systems (Tanita Corp., Tokyo, Japan). SUBJECTS: There were 40 subject evaluations in males (n=20) and females (n=20) ranging in age from 6 to 64 y. BIA was evaluated in each subject and compared to reference lean soft-tissue (LST) and %fat estimates in the appendages and remainder (trunk+head) provided by dual-energy X-ray absorptiometry (DXA). Appendicular LST (ALST) estimates from both BIA and DXA were used to derive total body SM mass. RESULTS: The highest correlation between total body LST by DXA and impedance index (Ht(2)/Z) by BC-418 was for the foot-hand segments (r=0.986; left side only) compared to the arm (r=0.970-0.979) and leg segments (r=0.942-0.957)(all P<0.001). The within- and between-day coefficient of variation for %fat and ALST evaluated in five subjects was <1% and approximately 1-3.7%, respectively. The correlations between 8-electrode predicted and DXA appendicular (arms, legs, total) and trunk+head LST were strong and highly significant (all r> or =0.95, P<0.001) and group means did not differ across methods. Skeletal muscle mass calculated (Kim equation) from total ALST by DXA (X+/-s.d.)(23.7+/-9.7 kg) was not significantly different and highly correlated with BC-418 estimates (25.2+/-9.6 kg; r=0.96, P<0.001). There was a good correlation between total body %fat by 8-electrode BIA vs DXA (r=0.87, P<0.001) that exceeded the corresponding association with 4-electrode BIA (r=0.82, P<0.001). Group mean segmental %fat estimates from BC-418 did not differ significantly from corresponding DXA estimates. No between-method bias was detected in the whole body, ALST, and skeletal muscle analyses. CONCLUSIONS: The new 8-electrode BIA system offers an important new opportunity of evaluating SM in research and clinical settings. The additional electrodes of the new BIA system also improve the association with DXA %fat estimates over those provided by the conventional foot-foot BIA

New bioimpedance analysis system: improved phenotyping with whole-body analysis.

Pietrobelli, Angelo;
2004-01-01

Abstract

OBJECTIVE: Bioimpedance analysis (BIA) is a potential field and clinical method for evaluating skeletal muscle mass (SM) and %fat. A new BIA system has 8-(two on each hand and foot) rather than 4-contact electrodes allowing for rapid 'whole-body' and regional body composition evaluation. DESIGN: This study evaluated the 50 kHz BC-418 8-contact electrode and TBF-310 4-contact electrode foot-foot BIA systems (Tanita Corp., Tokyo, Japan). SUBJECTS: There were 40 subject evaluations in males (n=20) and females (n=20) ranging in age from 6 to 64 y. BIA was evaluated in each subject and compared to reference lean soft-tissue (LST) and %fat estimates in the appendages and remainder (trunk+head) provided by dual-energy X-ray absorptiometry (DXA). Appendicular LST (ALST) estimates from both BIA and DXA were used to derive total body SM mass. RESULTS: The highest correlation between total body LST by DXA and impedance index (Ht(2)/Z) by BC-418 was for the foot-hand segments (r=0.986; left side only) compared to the arm (r=0.970-0.979) and leg segments (r=0.942-0.957)(all P<0.001). The within- and between-day coefficient of variation for %fat and ALST evaluated in five subjects was <1% and approximately 1-3.7%, respectively. The correlations between 8-electrode predicted and DXA appendicular (arms, legs, total) and trunk+head LST were strong and highly significant (all r> or =0.95, P<0.001) and group means did not differ across methods. Skeletal muscle mass calculated (Kim equation) from total ALST by DXA (X+/-s.d.)(23.7+/-9.7 kg) was not significantly different and highly correlated with BC-418 estimates (25.2+/-9.6 kg; r=0.96, P<0.001). There was a good correlation between total body %fat by 8-electrode BIA vs DXA (r=0.87, P<0.001) that exceeded the corresponding association with 4-electrode BIA (r=0.82, P<0.001). Group mean segmental %fat estimates from BC-418 did not differ significantly from corresponding DXA estimates. No between-method bias was detected in the whole body, ALST, and skeletal muscle analyses. CONCLUSIONS: The new 8-electrode BIA system offers an important new opportunity of evaluating SM in research and clinical settings. The additional electrodes of the new BIA system also improve the association with DXA %fat estimates over those provided by the conventional foot-foot BIA
2004
body measurements; total body water; BIA; adults; skeletal muscle mass evaluation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/364033
Citazioni
  • ???jsp.display-item.citation.pmc??? 106
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact