BACKGROUND: Myocardial revascularization with drug-eluting stents (DESs) is emerging as an alternative to conventional coronary artery bypass surgery in patients with multivessel coronary artery disease (MV-CAD). First-generation DESs have yielded equivalent safety results at mid-term compared with surgery, but inferior efficacy in preventing the recurrence of ischemic symptoms. The outcome of percutaneous coronary intervention with a second-generation everolimus DES as compared with a paclitaxel DES in patients with MV-CAD has not been established. AIM OF THE STUDY: The aim of the study is the assessment of the efficacy and performance of the XIENCE V everolimus-eluting stent in the treatment of de-novo coronary artery lesions in patients with MV-CAD. STUDY DESIGN: The study is composed of two parts: a prospective, double arm, randomized multicenter trial to assess the angiographic efficacy of the XIENCE V everolimus-eluting coronary stent system (EECSS) compared with the Taxus Liberté Paclitaxel Eluting Coronary Stent System (Taxus Liberté Stent) and a prospective, open-label, single arm, controlled registry to analyze the clinical efficacy and safety of XIENCE V EECSS at mid-term and long-term follow-up in patients treated for MV-CAD. ENDPOINTS: For the EXECUTIVE randomized trial, the primary endpoint is in-stent late lumen loss at 9 months. For the EXECUTIVE registry, the primary endpoint is a composite of all death, myocardial infarction (Q-wave and non-Q-wave), and ischemia-driven target vessel revascularization at 12 months. The study will be conducted at 30 study centers in Italy and 600 patients will be enrolled in total: 200 patients will be enrolled (1: 1) in the randomized trial and 400 patients will enter the registry. SAMPLE SIZE: It was calculated that, assuming a mean in-stent late lumen loss of 0.20 +/- 0.41 mm in the XIENCE V EECSS arm and 0.30 +/- 0.53 mm in the Taxus Liberté stent arm, and a noninferiority margin delta of 0.12 (according to the SPIRIT III results), the analysis of 81 lesions per arm would provide over 90\% power. Therefore, 200 patients will be enrolled to account for dropouts. CONCLUSION: The present study is expected to provide as yet unavailable information about the performance of second-generation stents in the specific setting of patients with MV-CAD.

A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease. Study design and rationale of the EXECUTIVE trial.

RIBICHINI, Flavio Luciano;VASSANELLI, Corrado;E. X. E. C. U. T. I. V. E. Trial Investigators
2010-01-01

Abstract

BACKGROUND: Myocardial revascularization with drug-eluting stents (DESs) is emerging as an alternative to conventional coronary artery bypass surgery in patients with multivessel coronary artery disease (MV-CAD). First-generation DESs have yielded equivalent safety results at mid-term compared with surgery, but inferior efficacy in preventing the recurrence of ischemic symptoms. The outcome of percutaneous coronary intervention with a second-generation everolimus DES as compared with a paclitaxel DES in patients with MV-CAD has not been established. AIM OF THE STUDY: The aim of the study is the assessment of the efficacy and performance of the XIENCE V everolimus-eluting stent in the treatment of de-novo coronary artery lesions in patients with MV-CAD. STUDY DESIGN: The study is composed of two parts: a prospective, double arm, randomized multicenter trial to assess the angiographic efficacy of the XIENCE V everolimus-eluting coronary stent system (EECSS) compared with the Taxus Liberté Paclitaxel Eluting Coronary Stent System (Taxus Liberté Stent) and a prospective, open-label, single arm, controlled registry to analyze the clinical efficacy and safety of XIENCE V EECSS at mid-term and long-term follow-up in patients treated for MV-CAD. ENDPOINTS: For the EXECUTIVE randomized trial, the primary endpoint is in-stent late lumen loss at 9 months. For the EXECUTIVE registry, the primary endpoint is a composite of all death, myocardial infarction (Q-wave and non-Q-wave), and ischemia-driven target vessel revascularization at 12 months. The study will be conducted at 30 study centers in Italy and 600 patients will be enrolled in total: 200 patients will be enrolled (1: 1) in the randomized trial and 400 patients will enter the registry. SAMPLE SIZE: It was calculated that, assuming a mean in-stent late lumen loss of 0.20 +/- 0.41 mm in the XIENCE V EECSS arm and 0.30 +/- 0.53 mm in the Taxus Liberté stent arm, and a noninferiority margin delta of 0.12 (according to the SPIRIT III results), the analysis of 81 lesions per arm would provide over 90\% power. Therefore, 200 patients will be enrolled to account for dropouts. CONCLUSION: The present study is expected to provide as yet unavailable information about the performance of second-generation stents in the specific setting of patients with MV-CAD.
2010
Angiography; Blood Vessel Prosthesis Implantation; Clinical Protocols; Coronary Artery Disease; Cost-Benefit Analysis; Drug-Eluting Stents; Humans; Immunosuppressive Agents; Myocardial Revascularization; Prospective Studies; Research Design; Sirolimus
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/345719
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact