The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy and precision testing were computed by software developed in our institution. This computer software can generate models of solid organs and allows both standard mouse-based and electromagnetic pen-driven segmentation (number of data sets, n = 70). The images used as input for rapidity testing was partly computed by modeling software (n = 70) and partly selected from contrast-enhanced computed tomography (CT) examinations (n = 12). Mean volumes and time required to perform the segmentation, along with standard deviation and range values with both techniques, were calculated. Student's t test was used to assess significance regarding mean volumes and time calculated by using both segmentation techniques on phantom and CT data sets. P value was also calculated. The mean volume difference was significantly lower with the use of the freehand electromagnetic pen as compared with the optical mouse (0.2% vs. 1.8%; P < .001). The mean segmentation time per patient was significantly shorter with the use of the freehand electromagnetic pen contourtracing method (354.5 vs. 499.1 s on phantoms; 457.4 vs. 610.0 s on CT images; P < .001). Freehand electromagnetic pen-based volumetric technique represents a technologic advancement over manual mouse-based contourtracing because of the superior statistical accuracy and sensibly shorter time required. Further studies focused on intra- and interobserver variability of the technique need to be performed before its introduction in clinical application.

Freehand Liver Volumetry by Using an Electromagnetic Pen Tablet: Accuracy, Precision, and Rapidity

FACCIOLI, Niccolò;POZZI MUCELLI, Roberto
2010-01-01

Abstract

The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy and precision testing were computed by software developed in our institution. This computer software can generate models of solid organs and allows both standard mouse-based and electromagnetic pen-driven segmentation (number of data sets, n = 70). The images used as input for rapidity testing was partly computed by modeling software (n = 70) and partly selected from contrast-enhanced computed tomography (CT) examinations (n = 12). Mean volumes and time required to perform the segmentation, along with standard deviation and range values with both techniques, were calculated. Student's t test was used to assess significance regarding mean volumes and time calculated by using both segmentation techniques on phantom and CT data sets. P value was also calculated. The mean volume difference was significantly lower with the use of the freehand electromagnetic pen as compared with the optical mouse (0.2% vs. 1.8%; P < .001). The mean segmentation time per patient was significantly shorter with the use of the freehand electromagnetic pen contourtracing method (354.5 vs. 499.1 s on phantoms; 457.4 vs. 610.0 s on CT images; P < .001). Freehand electromagnetic pen-based volumetric technique represents a technologic advancement over manual mouse-based contourtracing because of the superior statistical accuracy and sensibly shorter time required. Further studies focused on intra- and interobserver variability of the technique need to be performed before its introduction in clinical application.
2010
Liver volumetry; computed tomography (CT); pen tablet; contour tracing
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/341396
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 6
social impact