A multicenter study has been employed to evaluate the diagnostic efficacy of magnetic resonance imaging (MRI) using the new liver-specific contrast agent gadoxetic acid (Gd-EOB-DTPA, Primovist), as opposed to contrast-enhanced biphasic spiral computed tomography (CT), in the diagnosis of focal liver lesions, compared with a standard of reference (SOR). One hundred and sixty-nine patients with hepatic lesions eligible for surgery underwent Gd-EOB-DTPA-enhanced MRI as well as CT within 6 weeks. Pathologic evaluation of the liver specimen combined with intraoperative ultrasound established the SOR. Data sets were evaluated on-site (14 investigators) and off-site (three independent blinded readers). Gd-EOB-DTPA was well tolerated. Three hundred and two lesions were detected in 131 patients valid for analysis by SOR. The frequency of correctly detected lesions was significantly higher on Gd-EOB-DTPA-enhanced MRI compared with CT in the clinical evaluation [10.44%; 95% confidence interval (CI): 4.88, 16.0]. In the blinded reading there was a trend towards Gd-EOB-DTPA-enhanced MRI, not reaching statistical significance (2.14%; 95% CI: -4.32, 8.6). However, the highest rate of correctly detected lesions with a diameter below 1 cm was achieved by Gd-EOB-DTPA-enhanced MRI. Differential diagnosis was superior for Gd-EOB-DTPA-enhanced MRI (82.1%) versus CT (71.0%). A change in surgical therapy was documented in 19 of 131 patients (14.5%) post Gd-EOB-DTPA-enhanced MRI. Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT.

Diagnostic efficacy of gadoxetic acid (Primovist)-enhanced MRI and spiral CT for a therapeutic strategy: comparison with intraoperative and histopathologic findings in focal liver lesions

MANFREDI, Riccardo;
2008-01-01

Abstract

A multicenter study has been employed to evaluate the diagnostic efficacy of magnetic resonance imaging (MRI) using the new liver-specific contrast agent gadoxetic acid (Gd-EOB-DTPA, Primovist), as opposed to contrast-enhanced biphasic spiral computed tomography (CT), in the diagnosis of focal liver lesions, compared with a standard of reference (SOR). One hundred and sixty-nine patients with hepatic lesions eligible for surgery underwent Gd-EOB-DTPA-enhanced MRI as well as CT within 6 weeks. Pathologic evaluation of the liver specimen combined with intraoperative ultrasound established the SOR. Data sets were evaluated on-site (14 investigators) and off-site (three independent blinded readers). Gd-EOB-DTPA was well tolerated. Three hundred and two lesions were detected in 131 patients valid for analysis by SOR. The frequency of correctly detected lesions was significantly higher on Gd-EOB-DTPA-enhanced MRI compared with CT in the clinical evaluation [10.44%; 95% confidence interval (CI): 4.88, 16.0]. In the blinded reading there was a trend towards Gd-EOB-DTPA-enhanced MRI, not reaching statistical significance (2.14%; 95% CI: -4.32, 8.6). However, the highest rate of correctly detected lesions with a diameter below 1 cm was achieved by Gd-EOB-DTPA-enhanced MRI. Differential diagnosis was superior for Gd-EOB-DTPA-enhanced MRI (82.1%) versus CT (71.0%). A change in surgical therapy was documented in 19 of 131 patients (14.5%) post Gd-EOB-DTPA-enhanced MRI. Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT.
2008
Magnetic resonance imaging; Computed tomography; Focal liver lesions; Liver-specific; Hepatobiliary; Gadoxetic acid-enhanced MRI; Therapeutic strategy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/314559
Citazioni
  • ???jsp.display-item.citation.pmc??? 85
  • Scopus 340
  • ???jsp.display-item.citation.isi??? 321
social impact