BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulphate (EtS) are two ethanol metabolites that can be detected in serum up to 8 h after ethanol elimination. Their presence is therefore indicative of recent ethanol consumption in case of delayed sampling after an event (e.g. car crash). METHODS: A LC-ESI-MS-MS method for the determination of EtG and EtS in serum was developed and validated. Two product ions together with the parent ions were monitored for identification. Pentadeuterated-EtG was used as internal standard. RESULTS: Excellent linearity for EtG (from 0.22 to 45 micromol/l) and EtS (from 0.40 to 80 micromol/l) was observed (r(2)>or=0.9998). LOD and LLOQ were 0.04 and 0.20 micromol/l for EtG and 0.08 and 0.40 micromol/l for EtS, respectively. Accuracy (bias) and precision (relative standard deviation), studied at four different quality control levels, were always better than 7%. Matrix effects were found to be negligible. The method was applied to several samples obtained from known alcoholics and social drinkers. CONCLUSIONS: A sensitive and specific determination of EtG and EtS in serum samples was achieved despite a simple and fast sample preparation. To our knowledge, this is the first fully validated method for the simultaneous determination of the two alcohol metabolites in serum.

Ehtyl glucuronide and ethyl sulfate determination in serum by liquid chromatography-electrospray tandem mass spectrometry

POLETTINI, ALDO ELIANO
2007-01-01

Abstract

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulphate (EtS) are two ethanol metabolites that can be detected in serum up to 8 h after ethanol elimination. Their presence is therefore indicative of recent ethanol consumption in case of delayed sampling after an event (e.g. car crash). METHODS: A LC-ESI-MS-MS method for the determination of EtG and EtS in serum was developed and validated. Two product ions together with the parent ions were monitored for identification. Pentadeuterated-EtG was used as internal standard. RESULTS: Excellent linearity for EtG (from 0.22 to 45 micromol/l) and EtS (from 0.40 to 80 micromol/l) was observed (r(2)>or=0.9998). LOD and LLOQ were 0.04 and 0.20 micromol/l for EtG and 0.08 and 0.40 micromol/l for EtS, respectively. Accuracy (bias) and precision (relative standard deviation), studied at four different quality control levels, were always better than 7%. Matrix effects were found to be negligible. The method was applied to several samples obtained from known alcoholics and social drinkers. CONCLUSIONS: A sensitive and specific determination of EtG and EtS in serum samples was achieved despite a simple and fast sample preparation. To our knowledge, this is the first fully validated method for the simultaneous determination of the two alcohol metabolites in serum.
2007
ethyl glucuronide, ethyl sulphate, serum, LC-ESI-MS-MS
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/310060
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 49
social impact