Abstract The present paper presents monopolar recording of facial nerve antidromic potentials as an alternative technique to facial electromyography for the continuous monitoring of the facial nerve during acoustic neuroma surgery. The investigation involved 22 patients undergoing acoustic neuroma surgery via a retrosigmoid approach (tumour sizes ranging from 5 to 28 mm). Bipolar electrical stimulation of the marginalis mandibulae was performed to elicit facial nerve antidromic potentials. Stimulus intensity ranged from 2 to 6 mA with a delivery rate of 7/sec. A silver wire monopolar electrode positioned intracranially on the proximal portion of the acoustic facial bundle was used to record antidromic potentials. To define the specific origin of the action potentials and acquire normative data, monopolar and bipolar recordings of facial nerve antidromic potentials were performed in 15 subjects undergoing retrosigmoid vestibular neurectomy for Meniere's disease. The average facial nerve antidromic potential latency was 4.2 (+/- 0.6) msec in subjects with acoustic neuroma and 3.3 (+/- 0.2) msec in subjects with Meniere's disease. Facial nerve antidromic potentials furnished near real-time information about intraoperative facial nerve damage and postoperative facial nerve function during acoustic neuroma surgery. Facial nerve antidromic potentials may provide additional information to conventional EMG. They allow the use of endplate blockers, yield quantitative estimation of facial nerve conduction properties in terms of amplitude and latency, and allow actual continuous monitoring of the facial nerve.

Intraoperative monitoring of the facial nerve antidromic potentials during acoustic neuroma surgery

COLLETTI, Vittorio;
1997-01-01

Abstract

Abstract The present paper presents monopolar recording of facial nerve antidromic potentials as an alternative technique to facial electromyography for the continuous monitoring of the facial nerve during acoustic neuroma surgery. The investigation involved 22 patients undergoing acoustic neuroma surgery via a retrosigmoid approach (tumour sizes ranging from 5 to 28 mm). Bipolar electrical stimulation of the marginalis mandibulae was performed to elicit facial nerve antidromic potentials. Stimulus intensity ranged from 2 to 6 mA with a delivery rate of 7/sec. A silver wire monopolar electrode positioned intracranially on the proximal portion of the acoustic facial bundle was used to record antidromic potentials. To define the specific origin of the action potentials and acquire normative data, monopolar and bipolar recordings of facial nerve antidromic potentials were performed in 15 subjects undergoing retrosigmoid vestibular neurectomy for Meniere's disease. The average facial nerve antidromic potential latency was 4.2 (+/- 0.6) msec in subjects with acoustic neuroma and 3.3 (+/- 0.2) msec in subjects with Meniere's disease. Facial nerve antidromic potentials furnished near real-time information about intraoperative facial nerve damage and postoperative facial nerve function during acoustic neuroma surgery. Facial nerve antidromic potentials may provide additional information to conventional EMG. They allow the use of endplate blockers, yield quantitative estimation of facial nerve conduction properties in terms of amplitude and latency, and allow actual continuous monitoring of the facial nerve.
1997
Intraoperative monitoring; facial nerve; antidromic potentials; acoustic neuroma surgery
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/227347
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact