This contribution proposes a hybrid approach integrating transient test-based techniques with machine learning for automatic leak detection in water transmission mains. Transient numerical simulations calibrated using experimental tests are used to develop a data-driven method based on neural networks to identify leak locations and characteristics. The accuracy of leak localization is demonstrated using three different degrees of noise in terms of mean absolute error, ranging between 0.54 m and 2.1 m. This proposed hybrid approach shows prospects for in-field applications.
Hybrid Transient-Machine Learning Methodology for Leak Detection in Water Transmission Mains
Tavelli, Maurizio;
2024-01-01
Abstract
This contribution proposes a hybrid approach integrating transient test-based techniques with machine learning for automatic leak detection in water transmission mains. Transient numerical simulations calibrated using experimental tests are used to develop a data-driven method based on neural networks to identify leak locations and characteristics. The accuracy of leak localization is demonstrated using three different degrees of noise in terms of mean absolute error, ranging between 0.54 m and 2.1 m. This proposed hybrid approach shows prospects for in-field applications.File in questo prodotto:
| File | Dimensione | Formato | |
|---|---|---|---|
|
2024_CapponiMenapace.pdf
solo utenti autorizzati
Descrizione: Paper
Tipologia:
Versione dell'editore
Licenza:
Creative commons
Dimensione
5.39 MB
Formato
Adobe PDF
|
5.39 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |