Background: Osteoporosis in males is largely under-diagnosed and under-treated, with most of the diagnosis confirmed only after an osteoporotic fracture. Therefore, there is an urgent need for highly accurate and precise technologies capable of identifying osteoporosis earlier, thereby avoiding complications from fragility fractures. Aims: This study aimed to evaluate the diagnostic accuracy and precision of the non-ionizing technology Radiofrequency Echographic Multi Spectrometry (REMS) for the diagnosis of osteoporosis in a male population in comparison with conventional Dual-energy X-ray Absorptiometry (DXA). Methods: A cohort of 603 Caucasian males aged between 30 and 90 years were involved in the study. All the enrolled patients underwent lumbar and femoral scans with both DXA and REMS. The diagnostic agreement between REMS and DXA-measured BMD was expressed by Pearson correlation coefficient and Bland-Altman method. The accuracy of the diagnostic classification was evaluated by the assessment of sensitivity and specificity considering DXA as reference. Results: A significant correlation between REMS- and DXA-measured T-score values (r = 0.91, p < 0.0001) for lumbar spine and for femoral neck (r = 0.90, p < 0.0001) documented the substantial equivalence of the two measurement techniques. Bland-Altman outcomes showed that the average difference in T-score measurement is very close to zero (-0.06 ± 0.60 g/cm2 for lumbar spine and - 0.07 ± 0.44 g/cm2 for femoral neck) confirming the agreement between the two techniques. Furthermore, REMS resulted an effective technique to discriminate osteoporotic patients from the non-osteoporotic ones on both lumbar spine (sensitivity = 90.1%, specificity = 93.6%) and femoral neck (sensitivity = 90.9%, specificity = 94.6%). Precision yielded RMS-CV = 0.40% for spine and RMS-CV = 0.34% for femur. Conclusion: REMS, is a reliable technology for the diagnosis of osteoporosis also in men. This evidence corroborates its high diagnostic performance already observed in previous studies involving female populations.

Bone health status evaluation in men by means of REMS technology

Giovanni, Adami;Angelo, Fassio;Davide, Gatti;Maurizio, Rossini
2024-01-01

Abstract

Background: Osteoporosis in males is largely under-diagnosed and under-treated, with most of the diagnosis confirmed only after an osteoporotic fracture. Therefore, there is an urgent need for highly accurate and precise technologies capable of identifying osteoporosis earlier, thereby avoiding complications from fragility fractures. Aims: This study aimed to evaluate the diagnostic accuracy and precision of the non-ionizing technology Radiofrequency Echographic Multi Spectrometry (REMS) for the diagnosis of osteoporosis in a male population in comparison with conventional Dual-energy X-ray Absorptiometry (DXA). Methods: A cohort of 603 Caucasian males aged between 30 and 90 years were involved in the study. All the enrolled patients underwent lumbar and femoral scans with both DXA and REMS. The diagnostic agreement between REMS and DXA-measured BMD was expressed by Pearson correlation coefficient and Bland-Altman method. The accuracy of the diagnostic classification was evaluated by the assessment of sensitivity and specificity considering DXA as reference. Results: A significant correlation between REMS- and DXA-measured T-score values (r = 0.91, p < 0.0001) for lumbar spine and for femoral neck (r = 0.90, p < 0.0001) documented the substantial equivalence of the two measurement techniques. Bland-Altman outcomes showed that the average difference in T-score measurement is very close to zero (-0.06 ± 0.60 g/cm2 for lumbar spine and - 0.07 ± 0.44 g/cm2 for femoral neck) confirming the agreement between the two techniques. Furthermore, REMS resulted an effective technique to discriminate osteoporotic patients from the non-osteoporotic ones on both lumbar spine (sensitivity = 90.1%, specificity = 93.6%) and femoral neck (sensitivity = 90.9%, specificity = 94.6%). Precision yielded RMS-CV = 0.40% for spine and RMS-CV = 0.34% for femur. Conclusion: REMS, is a reliable technology for the diagnosis of osteoporosis also in men. This evidence corroborates its high diagnostic performance already observed in previous studies involving female populations.
2024
Bone fragility
Bone health status
Men
Osteoporosis
REMS
Radiofrequency Echographic Multi-Spectrometry
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1123046
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact