Background: Quadriceps strength testing is recommended to guide rehabilitation and mitigate the risk of second injury following anterior cruciate ligament (ACL) reconstruction. Hand-held dynamometry is a practical alternative to electromechanical dynamometry but demonstrates insufficient reliability and criterion validity in healthy and ACL-reconstructed participants respectively. The purpose of this study is to investigate the reliability and concurrent validity of inline dynamometry for measuring quadriceps strength. The hypotheses are that intra-class correlation coefficient (ICC) values will be >0.90 for reliability and concurrent validity. Methods: This was a cross sectional study using a within-participant, repeated measures design. Isometric quadriceps testing was performed at 60° knee flexion in 50 healthy and 52 ACL-reconstructed participants. Interrater reliability, intrarater reliability, and concurrent validity of inline dynamometry was investigated through calculation of ICCs, Bland-Altman analysis, linear regression, standard error of measurement (SEM) and minimal detectable change (MDC). Results: The lower bounds of the 95% confidence intervals were >0.90 for all reliability and validity ICCs in healthy and ACL-reconstructed participants, except for intrarater reliability in healthy participants using absolute scores (ICC = 0.936 [95% CI 0.890-0.963]). In ACL-reconstructed participants, Bland-Altman bias was 0.01 Nm/kg for absolute and average scores, limits of agreement were -11.74% to 12.59% for absolute scores, the SEM was 0.13Nm/kg (95% CI 0.10-0.17) and the MDC was 0.36Nm/kg (95% CI 0.28 - 0.47). Conclusion: Inline dynamometry is a reliable and economical alternative to electromechanical dynamometry for the assessment of quadriceps strength following ACL-reconstruction. Clinical trial registration number: ClinicalTrials.gov (NCT05109871).
Inline dynamometry provides reliable measurements of quadriceps strength in healthy and ACL-reconstructed individuals and is a valid substitute for isometric electromechanical dynamometry following ACL reconstruction
Morrison, Scot;
2024-01-01
Abstract
Background: Quadriceps strength testing is recommended to guide rehabilitation and mitigate the risk of second injury following anterior cruciate ligament (ACL) reconstruction. Hand-held dynamometry is a practical alternative to electromechanical dynamometry but demonstrates insufficient reliability and criterion validity in healthy and ACL-reconstructed participants respectively. The purpose of this study is to investigate the reliability and concurrent validity of inline dynamometry for measuring quadriceps strength. The hypotheses are that intra-class correlation coefficient (ICC) values will be >0.90 for reliability and concurrent validity. Methods: This was a cross sectional study using a within-participant, repeated measures design. Isometric quadriceps testing was performed at 60° knee flexion in 50 healthy and 52 ACL-reconstructed participants. Interrater reliability, intrarater reliability, and concurrent validity of inline dynamometry was investigated through calculation of ICCs, Bland-Altman analysis, linear regression, standard error of measurement (SEM) and minimal detectable change (MDC). Results: The lower bounds of the 95% confidence intervals were >0.90 for all reliability and validity ICCs in healthy and ACL-reconstructed participants, except for intrarater reliability in healthy participants using absolute scores (ICC = 0.936 [95% CI 0.890-0.963]). In ACL-reconstructed participants, Bland-Altman bias was 0.01 Nm/kg for absolute and average scores, limits of agreement were -11.74% to 12.59% for absolute scores, the SEM was 0.13Nm/kg (95% CI 0.10-0.17) and the MDC was 0.36Nm/kg (95% CI 0.28 - 0.47). Conclusion: Inline dynamometry is a reliable and economical alternative to electromechanical dynamometry for the assessment of quadriceps strength following ACL-reconstruction. Clinical trial registration number: ClinicalTrials.gov (NCT05109871).I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.