Flexible neural implants are extremely favored, as the most successful strategy to promote probe-tissue integration and avoid severe gliosis relies on reducing the mechanical mismatch between probe and brain tissue. But what are the realistic requirements for achieving chronic recording stability? What are the critical dimensions and main factors determining glial scar-free device integration? To answer these questions, two types of hair sized polyimide-based flexible intracortical (PIXI) arrays were fabricated, differing only in their cross-sectional area. Chronic tissue reaction to both types was evaluated in rats, and in different implantation setups. Interfacial stresses were found to play a critical role in long-term tissue integration. Still, all the devices provided high quality chronic recordings of single units and inflammatory gene expression was not significantly upregulated for larger devices. Our study points out that the most relevant factor in eliciting FBR is played by mechanical probe tissue interactions, that polyimide is well tolerated by the tissue, and that a holistic design considering material properties, geometrical dimensions and assembling techniques is the key towards longevity and long-term performance of intracortical probes. The optimization of only one parameter did not yet lead to the successful translation of research accomplishments into chronic preclinical and clinical applications.
On the longevity of flexible neural interfaces: Establishing biostability of polyimide-based intracortical implants
Ciarpella, Francesca;
2022-01-01
Abstract
Flexible neural implants are extremely favored, as the most successful strategy to promote probe-tissue integration and avoid severe gliosis relies on reducing the mechanical mismatch between probe and brain tissue. But what are the realistic requirements for achieving chronic recording stability? What are the critical dimensions and main factors determining glial scar-free device integration? To answer these questions, two types of hair sized polyimide-based flexible intracortical (PIXI) arrays were fabricated, differing only in their cross-sectional area. Chronic tissue reaction to both types was evaluated in rats, and in different implantation setups. Interfacial stresses were found to play a critical role in long-term tissue integration. Still, all the devices provided high quality chronic recordings of single units and inflammatory gene expression was not significantly upregulated for larger devices. Our study points out that the most relevant factor in eliciting FBR is played by mechanical probe tissue interactions, that polyimide is well tolerated by the tissue, and that a holistic design considering material properties, geometrical dimensions and assembling techniques is the key towards longevity and long-term performance of intracortical probes. The optimization of only one parameter did not yet lead to the successful translation of research accomplishments into chronic preclinical and clinical applications.| File | Dimensione | Formato | |
|---|---|---|---|
| 
									
										
										
										
										
											
												
												
												    
												
											
										
									
									
										
										
											Biomaterials 2022 On the longevity.pdf
										
																				
									
										
											 solo utenti autorizzati 
											Tipologia:
											Versione dell'editore
										 
									
									
									
									
										
											Licenza:
											
											
												Copyright dell'editore
												
												
												
											
										 
									
									
										Dimensione
										8.89 MB
									 
									
										Formato
										Adobe PDF
									 
										
										
								 | 
								8.89 MB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.