ObjectivesWe hypothesised that low flow low gradient aortic stenosis (LFLGAS) is associated with more severe coronary microvascular dysfunction (CMD) compared with normal-flow high-gradient aortic stenosis (NFHGAS) and that CMD is related to reduced cardiac performance. MethodsInvasive CMD assessment was performed in 41 consecutive patients with isolated severe aortic stenosis with unobstructed coronary arteries undergoing transcatheter aortic valve implantation (TAVI). The index of microcirculatory resistance (IMR), resistive reserve ratio (RRR) and coronary flow reserve (CFR) were measured in the left anterior descending artery before and after TAVI. Speckle tracking echocardiography was performed to assess cardiac function at baseline and repeated at 6 months. ResultsIMR was significantly higher in patients with LFLGAS compared with patients with NFHGAS (24.1 (14.6 to 39.1) vs 12.8 (8.6 to 19.2), p=0.002), while RRR was significantly lower (1.4 (1.1 to 2.1) vs 2.6 (1.5 to 3.3), p=0.020). No significant differences were observed in CFR between the two groups. High IMR was associated with low stroke volume index, low cardiac output and reduced peak atrial longitudinal strain (PALS). TAVI determined no significant variation in microvascular function (IMR: 16.0 (10.4 to 26.1) vs 16.6 (10.2 to 25.6), p=0.403) and in PALS (15.9 (9.9 to 26.5) vs 20.1 (12.3 to 26.7), p=0.222). Conversely, left ventricular (LV) global longitudinal strain increased after TAVI (-13.2 (8.4 to 16.6) vs -15.1 (9.4 to 17.8), p=0.047). In LFLGAS, LV systolic function recovered after TAVI in patients with preserved microvascular function but not in patients with CMD. ConclusionsCMD is more severe in patients with LFLGAS compared with NFHGAS and is associated with low-flow state, left atrial dysfunction and reduced cardiac performance.

Proof of concept study on coronary microvascular function in low flow low gradient aortic stenosis

Scarsini, Roberto;Pighi, Michele;Mainardi, Andrea;Portolan, Leonardo;Springhetti, Paolo;Mammone, Concetta;Della Mora, Francesco;Fanti, Diego;Tavella, Domenico;Gottin, Leonardo;Bergamini, Corinna;Benfari, Giovanni;Pesarini, Gabriele;Ribichini, Flavio Luciano
2023-01-01

Abstract

ObjectivesWe hypothesised that low flow low gradient aortic stenosis (LFLGAS) is associated with more severe coronary microvascular dysfunction (CMD) compared with normal-flow high-gradient aortic stenosis (NFHGAS) and that CMD is related to reduced cardiac performance. MethodsInvasive CMD assessment was performed in 41 consecutive patients with isolated severe aortic stenosis with unobstructed coronary arteries undergoing transcatheter aortic valve implantation (TAVI). The index of microcirculatory resistance (IMR), resistive reserve ratio (RRR) and coronary flow reserve (CFR) were measured in the left anterior descending artery before and after TAVI. Speckle tracking echocardiography was performed to assess cardiac function at baseline and repeated at 6 months. ResultsIMR was significantly higher in patients with LFLGAS compared with patients with NFHGAS (24.1 (14.6 to 39.1) vs 12.8 (8.6 to 19.2), p=0.002), while RRR was significantly lower (1.4 (1.1 to 2.1) vs 2.6 (1.5 to 3.3), p=0.020). No significant differences were observed in CFR between the two groups. High IMR was associated with low stroke volume index, low cardiac output and reduced peak atrial longitudinal strain (PALS). TAVI determined no significant variation in microvascular function (IMR: 16.0 (10.4 to 26.1) vs 16.6 (10.2 to 25.6), p=0.403) and in PALS (15.9 (9.9 to 26.5) vs 20.1 (12.3 to 26.7), p=0.222). Conversely, left ventricular (LV) global longitudinal strain increased after TAVI (-13.2 (8.4 to 16.6) vs -15.1 (9.4 to 17.8), p=0.047). In LFLGAS, LV systolic function recovered after TAVI in patients with preserved microvascular function but not in patients with CMD. ConclusionsCMD is more severe in patients with LFLGAS compared with NFHGAS and is associated with low-flow state, left atrial dysfunction and reduced cardiac performance.
2023
aortic valve stenosis
cardiac catheterization
echocardiography
heart failure, systolic
transcatheter aortic valve replacement
File in questo prodotto:
File Dimensione Formato  
proof of concept study on coronary microvascular function HEART 2022.pdf

accesso aperto

Tipologia: Versione dell'editore
Licenza: Copyright dell'editore
Dimensione 1.58 MB
Formato Adobe PDF
1.58 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1083772
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact