Ultrasound Superior Vena Cava (SVC) flow assessment is a common measure of systemic and cerebral perfusion, although accuracy is limited. The aim of this study was to evaluate whether any improvements in accuracy could be achieved by measuring stroke distance from the instantaneous mean velocity, rather than from peak velocity, and by directly tracing area from images obtained with a high frequency linear probe. Paired phase contrast magnetic resonance imaging (PCMRI) and ultrasound assessments of SVC flow were performed in a pilot cohort of 7 infants. Median postnatal age, corrected gestation and weight at scan were 7 (2-74) days, 34.8 (31.7-37.2) weeks 1870 (970-2660) g. Median interval between PCMRI and ultrasound scans was 0.3 (0.2-0.5) h. The methodology trialed here showed a better agreement with PCMRI (mean bias -8 mL/kg/min, LOA -25-+8 mL/kg/min), compared to both the original method reported by Kluckow et al. (mean bias + 42 mL/kg/min, LOA -53-+137 mL/kg/min), and our own prior adaptation (mean bias + 23 mL/kg/min, LOA -25-+71 mL/kg/min). Ultrasound assessment of SVC flow volume using the modifications described led to enhanced accuracy and decreased variability compared to prior techniques in a small cohort of premature infants.

Echocardiographic Quantification of Superior Vena Cava (SVC) Flow in Neonates: Pilot Study of Modified Technique

Ficial, Benjamim
;
Bonafiglia, Elena;Petoello, Enrico;Flore, Alice Iride;Nogara, Silvia;Tsatsaris, Nicola;
2022-01-01

Abstract

Ultrasound Superior Vena Cava (SVC) flow assessment is a common measure of systemic and cerebral perfusion, although accuracy is limited. The aim of this study was to evaluate whether any improvements in accuracy could be achieved by measuring stroke distance from the instantaneous mean velocity, rather than from peak velocity, and by directly tracing area from images obtained with a high frequency linear probe. Paired phase contrast magnetic resonance imaging (PCMRI) and ultrasound assessments of SVC flow were performed in a pilot cohort of 7 infants. Median postnatal age, corrected gestation and weight at scan were 7 (2-74) days, 34.8 (31.7-37.2) weeks 1870 (970-2660) g. Median interval between PCMRI and ultrasound scans was 0.3 (0.2-0.5) h. The methodology trialed here showed a better agreement with PCMRI (mean bias -8 mL/kg/min, LOA -25-+8 mL/kg/min), compared to both the original method reported by Kluckow et al. (mean bias + 42 mL/kg/min, LOA -53-+137 mL/kg/min), and our own prior adaptation (mean bias + 23 mL/kg/min, LOA -25-+71 mL/kg/min). Ultrasound assessment of SVC flow volume using the modifications described led to enhanced accuracy and decreased variability compared to prior techniques in a small cohort of premature infants.
2022
MRI
Phase-contrast MRI
SVC flow
cerebral blood flow
doppler
echocardiography
neonate
perfusion
preterm
systemic blood flow
File in questo prodotto:
File Dimensione Formato  
diagnostics-12-02083.pdf

accesso aperto

Descrizione: CC BY 4.0 publisher version
Tipologia: Versione dell'editore
Licenza: Creative commons
Dimensione 7.67 MB
Formato Adobe PDF
7.67 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1078908
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact