The white matter structures of the human brain can be represented using diffusion-weighted MRI tractography. Unfortunately, tractography is prone to find false-positive streamlines causing a severe decline in its specificity and limiting its feasibility in accurate structural brain connectivity analyses. Filtering algorithms have been proposed to reduce the number of invalid streamlines but the currently available filtering algorithms are not suitable to process data that contains motion artefacts which are typical in clinical research. We augmented the Convex Optimization Modelling for Microstructure Informed Tractography (COMMIT) algorithm to adjust for these signals drop-out motion artefacts. We demonstrate with comprehensive Monte-Carlo whole brain simulations and in vivo infant data that our robust algorithm is capable of properly filtering tractography reconstructions despite these artefacts. We evaluated the results using parametric and non-parametric statistics and our results demonstrate that if not accounted for, motion artefacts can have severe adverse effects in human brain structural connectivity analyses as well as in microstructural property mappings. In conclusion, the usage of robust filtering methods to mitigate motion related errors in tractogram filtering is highly beneficial, especially in clinical studies with uncooperative patient groups such as infants. With our presented robust augmentation and open-source implementation, robust tractogram filtering is readily available.

Incorporating outlier information into diffusion MRI tractogram filtering for robust structural brain connectivity and microstructural analyses

Mario Ocampo-Pineda;Alessandro Daducci
2021-01-01

Abstract

The white matter structures of the human brain can be represented using diffusion-weighted MRI tractography. Unfortunately, tractography is prone to find false-positive streamlines causing a severe decline in its specificity and limiting its feasibility in accurate structural brain connectivity analyses. Filtering algorithms have been proposed to reduce the number of invalid streamlines but the currently available filtering algorithms are not suitable to process data that contains motion artefacts which are typical in clinical research. We augmented the Convex Optimization Modelling for Microstructure Informed Tractography (COMMIT) algorithm to adjust for these signals drop-out motion artefacts. We demonstrate with comprehensive Monte-Carlo whole brain simulations and in vivo infant data that our robust algorithm is capable of properly filtering tractography reconstructions despite these artefacts. We evaluated the results using parametric and non-parametric statistics and our results demonstrate that if not accounted for, motion artefacts can have severe adverse effects in human brain structural connectivity analyses as well as in microstructural property mappings. In conclusion, the usage of robust filtering methods to mitigate motion related errors in tractogram filtering is highly beneficial, especially in clinical studies with uncooperative patient groups such as infants. With our presented robust augmentation and open-source implementation, robust tractogram filtering is readily available.
2021
Commit; Diffusion; Filtering; Imputation; Magnetic resonance imaging; Microstructure; Movement; Outlier; Robust; Structural connectivity; Tractography; Weighted modeling
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1057637
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact