Postoperative pancreatic fistula (POPF), the major driver of morbidity and mortality following pancreatectomy, is caused by an abnormal communication between the pancreatic ductal epithelium and another epithelial surface containing pancreas-derived, enzyme-rich fluid. There is a strong correlation between the amylase content in surgically-placed drains early in the postoperative course and the development of POPF. A simple and cheap method to determine the amylase content from the drain effluent has been eagerly advocated. Here, we developed an amylase optical biosensor, based on a surface plasmon resonance (SPR) plastic optical fiber (POF), metallized with a 60 nm layer of gold and interrogated with white light. The sensor was made specific by coupling it with an anti-amylase antibody. Each surface derivatization step was optimized and studied by XPS, contact angle, and fluorescence. The POF-biosensor was tested for its response to amylase in diluted drain effluents. The volume of sample required was 50 µL and the measurement time was 8 min. The POF-biosensor showed selectivity for amylase, a calibration curve log-linear in the range of 0.8–25.8 U/L and a limit of detection (LOD) of ~0.5 U/L. In preliminary tests, the POF-biosensor allowed for the measurement of the amylase content of diluted surgically-placed drain effluents with an accuracy of >92% with respect to the gold standard. The POF-biosensor allows for reliable measurement and could be implemented to allow for a rapid bedside assessment of amylase value in drains following pancreatectomy.

A Surface Plasmon Resonance Plastic Optical Fiber Biosensor for the Detection of Pancreatic Amylase in Surgically-Placed Drain Effluent

Giuseppe Malleo;Deborah Bonamini;Roberto Salvia;Claudio Bassi;Alessandra Maria Bossi
2021-01-01

Abstract

Postoperative pancreatic fistula (POPF), the major driver of morbidity and mortality following pancreatectomy, is caused by an abnormal communication between the pancreatic ductal epithelium and another epithelial surface containing pancreas-derived, enzyme-rich fluid. There is a strong correlation between the amylase content in surgically-placed drains early in the postoperative course and the development of POPF. A simple and cheap method to determine the amylase content from the drain effluent has been eagerly advocated. Here, we developed an amylase optical biosensor, based on a surface plasmon resonance (SPR) plastic optical fiber (POF), metallized with a 60 nm layer of gold and interrogated with white light. The sensor was made specific by coupling it with an anti-amylase antibody. Each surface derivatization step was optimized and studied by XPS, contact angle, and fluorescence. The POF-biosensor was tested for its response to amylase in diluted drain effluents. The volume of sample required was 50 µL and the measurement time was 8 min. The POF-biosensor showed selectivity for amylase, a calibration curve log-linear in the range of 0.8–25.8 U/L and a limit of detection (LOD) of ~0.5 U/L. In preliminary tests, the POF-biosensor allowed for the measurement of the amylase content of diluted surgically-placed drain effluents with an accuracy of >92% with respect to the gold standard. The POF-biosensor allows for reliable measurement and could be implemented to allow for a rapid bedside assessment of amylase value in drains following pancreatectomy.
2021
optical fiber sensors; surface plasmon resonance; plastic optical fibers; antibody; amylase; postoperative pancreatic fistula
File in questo prodotto:
File Dimensione Formato  
sensors-21-03443-v2.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1043808
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact