Forensic inquests, particularly, in assessing time since death currently recognize the importance of the analysis of vitreous humour (VH) biomarkers. Present research, studies, and validates the determination of lactate (La) in VH by CZE with indirect UV detection. The BGE (pH 8.9) consisted of Tris buffer (37 mM) containing 4-methoxybenzoic acid (4 mM) and alkyl-trimethyl-ammonium bromide (1.2 mM). Each VH specimen was diluted with a butyric acid solution (internal standard 0.057 mM) and La and butyrate were separated within 3-5 min (30 kV). The La LOQ and LOD were 4 and 2 mM, respectively. The calibration curve linearity ranged from 4 to 80 mM; intra- and interruns precisions were less than 10% for standard as well as for VH specimen, respectively. To investigate postmortem interval (PMI) and VH lactate level correlation, human VH specimens were collected during autopsy (n = 40) and stored at -20°C until assay. La levels ranged from 16 to 42 mM; PMI values ranged from 10 to 141 h. La (mM) and PMI (h) correlation was statistically significant (r2 = 0.527; p < 0.05). In conclusion, the present CZE analysis is efficacious to determine VH La as a biomarker for PMI investigation

Lactate determination in human vitreous humour by capillary electrophoresis and time of death investigation

Bertaso A
Formal Analysis
;
Cirielli V
Resources
;
Tagliaro F.
Supervision
2020-01-01

Abstract

Forensic inquests, particularly, in assessing time since death currently recognize the importance of the analysis of vitreous humour (VH) biomarkers. Present research, studies, and validates the determination of lactate (La) in VH by CZE with indirect UV detection. The BGE (pH 8.9) consisted of Tris buffer (37 mM) containing 4-methoxybenzoic acid (4 mM) and alkyl-trimethyl-ammonium bromide (1.2 mM). Each VH specimen was diluted with a butyric acid solution (internal standard 0.057 mM) and La and butyrate were separated within 3-5 min (30 kV). The La LOQ and LOD were 4 and 2 mM, respectively. The calibration curve linearity ranged from 4 to 80 mM; intra- and interruns precisions were less than 10% for standard as well as for VH specimen, respectively. To investigate postmortem interval (PMI) and VH lactate level correlation, human VH specimens were collected during autopsy (n = 40) and stored at -20°C until assay. La levels ranged from 16 to 42 mM; PMI values ranged from 10 to 141 h. La (mM) and PMI (h) correlation was statistically significant (r2 = 0.527; p < 0.05). In conclusion, the present CZE analysis is efficacious to determine VH La as a biomarker for PMI investigation
2020
Capillary zone electrophoresis; Indirect UV detection; Lactate; Postmortem interval; Vitreous humour
File in questo prodotto:
File Dimensione Formato  
Lactate determinatio in human vitreous humour by capillary electrophoresis and time of death investigation.pdf

solo utenti autorizzati

Descrizione: Lavoro a stampa
Tipologia: Documento in Post-print
Licenza: Accesso ristretto
Dimensione 504.86 kB
Formato Adobe PDF
504.86 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1026601
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact