Long-term variations of fractional flow reserve (FFR) and instantaneous wave-free-ratio (iFR) after transcatheter aortic valve implantation (TAVI) have not been previously assessed. A total of 23 coronary lesions in 14 patients with aortic stenosis (AS) underwent physiology assessment at baseline, immediately after TAVI and at 14(7-29) months of follow-up. The angiographic severity of the lesions did not progress at follow-up (54[45-64] vs 54[49-63], p = .53). Overall, FFR (0.87[0.85-0.92] vs 0.88[0.82-0.92], p = .45) and iFR (0.88[0.85-0.96] vs 0.91[0.86-0.97], p = .30) did not change significantly compared with the baseline. FFR decreased in 3(13%) lesions with abnormal baseline value, whereas it remained stable in lesions with FFR > 0.80. Conversely, iFR did not show a systematic trend at long-term after TAVI. However, iFR demonstrated a higher reclassification rate at follow-up compared with FFR (p = .02). In conclusions, in this exploratory study, only minor variations of coronary physiology indices were observed at long-term after TAVI. Nevertheless, caution should be exercised in the interpretation of borderline FFR and iFR values in severe AS.

Long-term variations of FFR and iFR after transcatheter aortic valve implantation

Scarsini, Roberto;Lunardi, Mattia;Venturi, Gabriele;Pighi, Michele;Tavella, Domenico;Pesarini, Gabriele;Ribichini, Flavio
2020-01-01

Abstract

Long-term variations of fractional flow reserve (FFR) and instantaneous wave-free-ratio (iFR) after transcatheter aortic valve implantation (TAVI) have not been previously assessed. A total of 23 coronary lesions in 14 patients with aortic stenosis (AS) underwent physiology assessment at baseline, immediately after TAVI and at 14(7-29) months of follow-up. The angiographic severity of the lesions did not progress at follow-up (54[45-64] vs 54[49-63], p = .53). Overall, FFR (0.87[0.85-0.92] vs 0.88[0.82-0.92], p = .45) and iFR (0.88[0.85-0.96] vs 0.91[0.86-0.97], p = .30) did not change significantly compared with the baseline. FFR decreased in 3(13%) lesions with abnormal baseline value, whereas it remained stable in lesions with FFR > 0.80. Conversely, iFR did not show a systematic trend at long-term after TAVI. However, iFR demonstrated a higher reclassification rate at follow-up compared with FFR (p = .02). In conclusions, in this exploratory study, only minor variations of coronary physiology indices were observed at long-term after TAVI. Nevertheless, caution should be exercised in the interpretation of borderline FFR and iFR values in severe AS.
2020
Aortic stenosis
Coronary artery disease
Fractional flow reserve
Instantaneous wave-free ratio
Long-term
Transcatheter aortic valve implantation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1023172
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact