Aims: Despite similar efficacy and safety profile in pilot studies, bioresorbable polymer drug-eluting stents (BP-DES) could have potential benefit over latest generation durable polymer (DP)-DES by facilitating vessel healing, therefore reducing inflammation and neoatherosclerosis leading to enhanced clinical safety. Therefore, we sought to perform a meta-analysis of randomized clinical trials (RCTs) comparing the safety and efficacy of everolimus-eluting BP-DES (BP-EES) to second-generation DP-DES.Methods and results: We conducted a systematic review and meta-analysis to examine the safety and efficacy of BP-EES in patients treated for coronary artery disease. We searched PubMed, Scopus, and the Cochrane Library through February 2018 for RCTs that included outcome data on BP-EES. We identified four eligible studies, which included a total of 4631 patients. Three studies reported a follow-up of one year and one study of five years. The BP-EES group, included 2315 patients and the DP-DES group included 2316 patients (1143 treated with DP-EES and 1173 treated with zotarolimus eluting DP-DES). Patient's characteristics were comparable between the two groups except for higher prevalence of prior MI in the DP-DES group (25.7 vs 22.5%, respectively, p = 0.001). Procedural characteristics were comparable among groups except for slightly longer lesions in the BP-EES group compared to the DP-DES group (mean 15.1 vs 14.9mm, p = 0.04). No significant differences were observed for cardiacmortality (p = 0.72), occurrence of MI (p = 0.64), any TLR(p = 0.93), ST (p = 0.85) or major adverse cardiac events (p = 0.43).Conclusion: Overall, based on the available data BP-EES had similar one-year outcomes to contemporary DP-DES. Whether these devices could enhance clinical safety remains to be evaluated at longer follow-up. (c) 2018 Elsevier B.V. All rights reserved.

Comparison of the biodegradable polymer everolimus-eluting stent with contemporary drug-eluting stents: A systematic review and meta-analysis

Pighi, Michele;Vinco, Giulia;
2019-01-01

Abstract

Aims: Despite similar efficacy and safety profile in pilot studies, bioresorbable polymer drug-eluting stents (BP-DES) could have potential benefit over latest generation durable polymer (DP)-DES by facilitating vessel healing, therefore reducing inflammation and neoatherosclerosis leading to enhanced clinical safety. Therefore, we sought to perform a meta-analysis of randomized clinical trials (RCTs) comparing the safety and efficacy of everolimus-eluting BP-DES (BP-EES) to second-generation DP-DES.Methods and results: We conducted a systematic review and meta-analysis to examine the safety and efficacy of BP-EES in patients treated for coronary artery disease. We searched PubMed, Scopus, and the Cochrane Library through February 2018 for RCTs that included outcome data on BP-EES. We identified four eligible studies, which included a total of 4631 patients. Three studies reported a follow-up of one year and one study of five years. The BP-EES group, included 2315 patients and the DP-DES group included 2316 patients (1143 treated with DP-EES and 1173 treated with zotarolimus eluting DP-DES). Patient's characteristics were comparable between the two groups except for higher prevalence of prior MI in the DP-DES group (25.7 vs 22.5%, respectively, p = 0.001). Procedural characteristics were comparable among groups except for slightly longer lesions in the BP-EES group compared to the DP-DES group (mean 15.1 vs 14.9mm, p = 0.04). No significant differences were observed for cardiacmortality (p = 0.72), occurrence of MI (p = 0.64), any TLR(p = 0.93), ST (p = 0.85) or major adverse cardiac events (p = 0.43).Conclusion: Overall, based on the available data BP-EES had similar one-year outcomes to contemporary DP-DES. Whether these devices could enhance clinical safety remains to be evaluated at longer follow-up. (c) 2018 Elsevier B.V. All rights reserved.
2019
Biodegradable polymer; Coronary artery disease; Durable polymer; Everolimus; SYNERGY; Absorbable Implants; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Randomized Controlled Trials as Topic
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1013444
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 22
social impact