Background and aim of the work: Surface replacement arthroplasty (SRA) is an alternative to stemmed total hip arthroplasty (THA) providing a femoral bone preserving procedure. Because of the wider surgical dissection, an increased blood loss could be expected. This retrospective study evaluates the transfusion requirement in two homogeneous groups of patients who underwent primary hip replacement electively. Methods: Perioperative haematological data of 42 hip resurfacing procedures and 41 conventional cementless THAs were compared. The pre- and post-operative haemoglobin (Hb) levels and the amount of blood transfusions were registered. The median values were compared with use of the non-parametric Wilcoxon signedrank test. Results: In the SRA group, a significantly increased (p<0.02) preoperative Hb concentration (13.1 g/dL, range 10.9 to 15.6) was detected in comparison with the THA group (12.5 g/dL, range 10.4 to 15.2). In the resurfacing procedures a median of 900 mL (range 600 to 1500) were transfused vs. 600 (range 300 to 1500) in the conventional THAs, demonstrating a significantly higher transfusion requirement (p<0.04). Conclusions: Whereas hip resurfacing is a femoral bone preserving alternative to conventional THA with comparable clinical and radiographic outcomes, higher blood loss and transfusion requirement may occur.

Higher blood loss and transfusion requirement in surface arthroplasty versus conventional total hip replacement

Regis, Dario
;
Sandri, Andrea;Sambugaro, Elena;Vecchini, Eugenio;Samaila, Elena;Magnan, Bruno
2019-01-01

Abstract

Background and aim of the work: Surface replacement arthroplasty (SRA) is an alternative to stemmed total hip arthroplasty (THA) providing a femoral bone preserving procedure. Because of the wider surgical dissection, an increased blood loss could be expected. This retrospective study evaluates the transfusion requirement in two homogeneous groups of patients who underwent primary hip replacement electively. Methods: Perioperative haematological data of 42 hip resurfacing procedures and 41 conventional cementless THAs were compared. The pre- and post-operative haemoglobin (Hb) levels and the amount of blood transfusions were registered. The median values were compared with use of the non-parametric Wilcoxon signedrank test. Results: In the SRA group, a significantly increased (p<0.02) preoperative Hb concentration (13.1 g/dL, range 10.9 to 15.6) was detected in comparison with the THA group (12.5 g/dL, range 10.4 to 15.2). In the resurfacing procedures a median of 900 mL (range 600 to 1500) were transfused vs. 600 (range 300 to 1500) in the conventional THAs, demonstrating a significantly higher transfusion requirement (p<0.04). Conclusions: Whereas hip resurfacing is a femoral bone preserving alternative to conventional THA with comparable clinical and radiographic outcomes, higher blood loss and transfusion requirement may occur.
2019
Blood lossHb levelHip resurfacingTotal hip arthroplastyTransfusion requirement
File in questo prodotto:
File Dimensione Formato  
higher blood loss and transfusion requirement in surface arthroplasty versus conventional total hip replacemnt ACTA 2019.pdf

solo utenti autorizzati

Descrizione: articolo in rivista
Tipologia: Versione dell'editore
Licenza: Accesso ristretto
Dimensione 529.61 kB
Formato Adobe PDF
529.61 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1008655
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact