The aim of this cohort study was to investigate the relationship between crestal bone levels and crown-to-implant ratio of ultra-short implants, after functional loading. Sixty patients with single or partial edentulism and alveolar bone atrophy were enrolled and treated between December 2009 and January 2016. Without using bone-grafting procedures, patients were rehabilitated with ultra-short implants characterized by a microrough surface and a 6-mm length. Clinical and anatomical crown-to-implant (C/I) ratios and crestal bone levels (CBL) were measured after a follow-up period ranging from 12 to 72 months; all peri-implant and prosthetic parameters were recorded. The data collected were statistically analyzed ( P = .05). A total of 47 patients with 66 ultra-short implants were completely followed up according to described protocol. The mean follow-up was 48.5 ± 19.1 months. The mean anatomical C/I ratio was 2.2, while the mean clinical C/I ratio was 2.6 ± 0.6 at baseline and 2.8 ± 0.6 at the last follow-up appointment. Mean CBL as calculated at the baseline was 0.7 ± 0.5 mm, while at the last appointment it measured 1.0 ± 0.5 mm. The overall implant-based success rate was 96.9%, and the mean peri-implant bone loss (PBL) was 0.3 ± 0.3 mm. No statistically significant relationship was found between anatomical or clinical C/I ratio and PBL. Ultra-short implants appear to offer a predictable solution for implant-prosthetic rehabilitation in patients with edentulism and bone atrophy. A high percentage of implants were successful, with minimal crestal bone loss. The high C/I ratio did not appear to influence either peri-implant bone loss or prosthetic complication rates.

Relationship Between Crestal Bone Levels and Crown-to-Implant Ratio of Ultra-Short Implants With a Microrough Surface: A Prospective Study With 48 Months of Follow-Up

Malchiodi, Luciano;Bertossi, Dario;
2019-01-01

Abstract

The aim of this cohort study was to investigate the relationship between crestal bone levels and crown-to-implant ratio of ultra-short implants, after functional loading. Sixty patients with single or partial edentulism and alveolar bone atrophy were enrolled and treated between December 2009 and January 2016. Without using bone-grafting procedures, patients were rehabilitated with ultra-short implants characterized by a microrough surface and a 6-mm length. Clinical and anatomical crown-to-implant (C/I) ratios and crestal bone levels (CBL) were measured after a follow-up period ranging from 12 to 72 months; all peri-implant and prosthetic parameters were recorded. The data collected were statistically analyzed ( P = .05). A total of 47 patients with 66 ultra-short implants were completely followed up according to described protocol. The mean follow-up was 48.5 ± 19.1 months. The mean anatomical C/I ratio was 2.2, while the mean clinical C/I ratio was 2.6 ± 0.6 at baseline and 2.8 ± 0.6 at the last follow-up appointment. Mean CBL as calculated at the baseline was 0.7 ± 0.5 mm, while at the last appointment it measured 1.0 ± 0.5 mm. The overall implant-based success rate was 96.9%, and the mean peri-implant bone loss (PBL) was 0.3 ± 0.3 mm. No statistically significant relationship was found between anatomical or clinical C/I ratio and PBL. Ultra-short implants appear to offer a predictable solution for implant-prosthetic rehabilitation in patients with edentulism and bone atrophy. A high percentage of implants were successful, with minimal crestal bone loss. The high C/I ratio did not appear to influence either peri-implant bone loss or prosthetic complication rates.
2019
; Cohort Studies; Crowns; Dental Implantation, Endosseous; Dental Prosthesis, Implant-Supported; Follow-Up Studies; Humans; Prospective Studies; Alveolar Bone Loss; Dental Implants; Dental Prosthesis Design
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1002252
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 16
social impact