Patient-specific finite element (FE) modeling is largely used to quantify mitral valve (MV) biomechanics associated to pathological and post-surgical conditions. We used this approach, integrated with non-invasive cardiac magnetic resonance (CMR) imaging data, to numerically perform the repair of the isolated mitral valve leaflet prolapse through expanded-polytetrafluoroethylene (ePTFE) sutures and quantitatively compare the effects of different techniques of neochordal implantation (NCI). CMR-derived FE models well reproduced MVP-related alterations and were able to assess the efficacy of each repairing technique and its biomechanical effects onMVapparatus; the quantification of biomechanical differences between NCI techniques, especially in terms of both chordal tensions and leaflet stresses redistribution, may impact on the short- and long-term the clinical outcome, potentially opening the way to patient-specific optimization of NCIs and, if extensively and successfully tested, improve surgical planning.

Repair of mitral valve prolapse through ePTFE Neochordae: A finite element approach from CMR

Sturla, Francesco;ONORATI, FRANCESCO;MILANO, Aldo Domenico;PECHLIVANIDIS, KONSTANTINOS;PUPPINI, Giovanni;REDAELLI, ANDREA;FAGGIAN, Giuseppe
2015-01-01

Abstract

Patient-specific finite element (FE) modeling is largely used to quantify mitral valve (MV) biomechanics associated to pathological and post-surgical conditions. We used this approach, integrated with non-invasive cardiac magnetic resonance (CMR) imaging data, to numerically perform the repair of the isolated mitral valve leaflet prolapse through expanded-polytetrafluoroethylene (ePTFE) sutures and quantitatively compare the effects of different techniques of neochordal implantation (NCI). CMR-derived FE models well reproduced MVP-related alterations and were able to assess the efficacy of each repairing technique and its biomechanical effects onMVapparatus; the quantification of biomechanical differences between NCI techniques, especially in terms of both chordal tensions and leaflet stresses redistribution, may impact on the short- and long-term the clinical outcome, potentially opening the way to patient-specific optimization of NCIs and, if extensively and successfully tested, improve surgical planning.
2015
978-3-319-10980-0
Biomechanics; Diagnostic products; Magnetic resonance; Repair; Surgery
File in questo prodotto:
File Dimensione Formato  
Sturla 2015 - Repair of MV prolaps through ePTFE neochordae - a FE approach from CMR.pdf

solo utenti autorizzati

Tipologia: Versione dell'editore
Licenza: Dominio pubblico
Dimensione 586.14 kB
Formato Adobe PDF
586.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/953568
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact