Background: The determination of Carbohydrate Deficient Transferrin (CDT) in a forensic context should be based on the use of a screening technique followed, for the "positive samples", by a confirmatory technique. The aim of this study was to compare the two most used automated screening methods for CDT analysis, immuno-nephelometric assay (INA) and multi-capillary electrophoresis (mCE), with a validated HPLC procedure, used as confirmation test, in order to re-evaluate the cut-off concentrations of the screening methods. Methods: 195 serum samples underwent CDT analysis by using the N Latex CDT direct immuno-nephelometric assay, the multicapillary system Capillarys™ and an anion exchange HPLC method with UV-visible detection at 460. nm developed and validated at our laboratories. Statistical analyses were performed by using Bland-Altman plots and ROC curves. Results and discussion: The 95% limits of agreement were ± 0.94% when comparing INA and HPLC and ± 0.60% when comparing mCE and HPLC. The ROC analysis of both INA and mCE, using HPLC as the reference method, showed that no false negative results were found when the cut-off was fixed to 1.2% for mCE and to 2.3% for INA. Conclusions: The study showed a good agreement among CDT determinations carried out either with mCE or INA or HPLC. However, the usual cut-offs of both mCE (1.3%) and INA (2.5%) should be lowered to minimize false negatives at the screening analysis.

Re-assessment of the cut-off levels of Carbohydrate Deficient Transferrin (CDT) for automated immunoassay and multi-capillary electrophoresis for application in a forensic context

Bortolotti F;Vandoros A;Tagliaro F
2013-01-01

Abstract

Background: The determination of Carbohydrate Deficient Transferrin (CDT) in a forensic context should be based on the use of a screening technique followed, for the "positive samples", by a confirmatory technique. The aim of this study was to compare the two most used automated screening methods for CDT analysis, immuno-nephelometric assay (INA) and multi-capillary electrophoresis (mCE), with a validated HPLC procedure, used as confirmation test, in order to re-evaluate the cut-off concentrations of the screening methods. Methods: 195 serum samples underwent CDT analysis by using the N Latex CDT direct immuno-nephelometric assay, the multicapillary system Capillarys™ and an anion exchange HPLC method with UV-visible detection at 460. nm developed and validated at our laboratories. Statistical analyses were performed by using Bland-Altman plots and ROC curves. Results and discussion: The 95% limits of agreement were ± 0.94% when comparing INA and HPLC and ± 0.60% when comparing mCE and HPLC. The ROC analysis of both INA and mCE, using HPLC as the reference method, showed that no false negative results were found when the cut-off was fixed to 1.2% for mCE and to 2.3% for INA. Conclusions: The study showed a good agreement among CDT determinations carried out either with mCE or INA or HPLC. However, the usual cut-offs of both mCE (1.3%) and INA (2.5%) should be lowered to minimize false negatives at the screening analysis.
2013
Capillary array electrophoresis, Carbohydrate Deficient Transferrin, CDT, Cut-off concentration, HPLC, Immunoassay
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/515950
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact