A method for quantifying the outcome of goal-directed postural pointing was presented and used for relating the tremor output to the oscillations of single arm landmarks. The displacement of reflective markers placed on shoulder, upper arm, forearm, and hand were measured by an optoelectronic motion capture system in nine subjects holding a laser penlight pointed at a target. The high signal-to-noise ratio of the measured displacement series (from 7:1 for shoulder marker to 30:1 for hand marker) demonstrated the feasibility of the proposed system to carry out tremor analysis. The track of the laser emission on the target, reconstructed from penlight displacements, was studied as the outcome of the pointing task. By measuring the length and the dispersion of the path covered by the target track in 30 s, a significant and comparable tremor amplitude was found in vertical and lateral directions. The correlation between target track and arm tremor was stronger for distal than for proximal markers. Spectral and cross-spectral analyses evidenced the presence of a dominant low frequency oscillation (1.5 Hz), along with a high frequency one (5–7 Hz), in the displacement of the target track. These two components were significantly linked to the oscillations of the hand, the forearm and the upper arm but not to those of the shoulder, suggesting that the oscillations in the overall tremor output during the pointing task are mainly generated by the arm segments.

Quantifying the contribution of arm postural tremor to the outcome of goal-directed pointing task by displacement measures.

PELLEGRINI, Barbara;SCHENA, Federico
2004-01-01

Abstract

A method for quantifying the outcome of goal-directed postural pointing was presented and used for relating the tremor output to the oscillations of single arm landmarks. The displacement of reflective markers placed on shoulder, upper arm, forearm, and hand were measured by an optoelectronic motion capture system in nine subjects holding a laser penlight pointed at a target. The high signal-to-noise ratio of the measured displacement series (from 7:1 for shoulder marker to 30:1 for hand marker) demonstrated the feasibility of the proposed system to carry out tremor analysis. The track of the laser emission on the target, reconstructed from penlight displacements, was studied as the outcome of the pointing task. By measuring the length and the dispersion of the path covered by the target track in 30 s, a significant and comparable tremor amplitude was found in vertical and lateral directions. The correlation between target track and arm tremor was stronger for distal than for proximal markers. Spectral and cross-spectral analyses evidenced the presence of a dominant low frequency oscillation (1.5 Hz), along with a high frequency one (5–7 Hz), in the displacement of the target track. These two components were significantly linked to the oscillations of the hand, the forearm and the upper arm but not to those of the shoulder, suggesting that the oscillations in the overall tremor output during the pointing task are mainly generated by the arm segments.
2004
Physiological tremor; Motor control; Goal-directed pointing; Human movement analysis; Spectral analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/234264
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 19
social impact