BACKGROUND:Despite the widespread use of fractional exhaled nitric oxide (FENO) as a biomarker of airways inflammation, there are no published papers describing normal FENO values in a large group of healthy adults.OBJECTIVE:The aim of this study was to establish adult FENO reference values according to the international guidelines.METHODS:FENO was measured in 204 healthy, non-smoking adults with normal spirometry values using the on-line single-breath technique, and the results were analysed chemiluminescently.RESULTS:The main result of the study was the significant difference in FENO values between men and women, thus indicating that gender-based reference FENO values are necessary. The FENO levels obtained at expiratory flows of 50 ml/s ranged from 2.6 to 28.8 ppb in men, and from 1.6 to 21.5 ppb in women.CONCLUSION:We propose reference FENO values for healthy adult men and women that could be used for clinical and research purposes.

Reference values for exaled nitric oxide (reveno) study.

Olivieri, Mario;PERBELLINI, Luigi;
2006-01-01

Abstract

BACKGROUND:Despite the widespread use of fractional exhaled nitric oxide (FENO) as a biomarker of airways inflammation, there are no published papers describing normal FENO values in a large group of healthy adults.OBJECTIVE:The aim of this study was to establish adult FENO reference values according to the international guidelines.METHODS:FENO was measured in 204 healthy, non-smoking adults with normal spirometry values using the on-line single-breath technique, and the results were analysed chemiluminescently.RESULTS:The main result of the study was the significant difference in FENO values between men and women, thus indicating that gender-based reference FENO values are necessary. The FENO levels obtained at expiratory flows of 50 ml/s ranged from 2.6 to 28.8 ppb in men, and from 1.6 to 21.5 ppb in women.CONCLUSION:We propose reference FENO values for healthy adult men and women that could be used for clinical and research purposes.
2006
Breath Tests*/methods; Nitric Oxide/analysis; Practice Guidelines as Topic; Reference Values; Reproducibility of Results; Sex Factors; Spirometry
File in questo prodotto:
File Dimensione Formato  
Perbellini Resp Research 2006.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 248.53 kB
Formato Adobe PDF
248.53 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/233273
Citazioni
  • ???jsp.display-item.citation.pmc??? 36
  • Scopus 129
  • ???jsp.display-item.citation.isi??? 121
social impact