The differential diagnosis of hepatic cystic echinococcosis (CE) may be challenging. When imaging is insufficient, serology can be applied, but no consensus diagnostic algorithm exists. We evaluated the performances of nine serological tests commercialized in Europe for the diagnosis of "echinococcosis". We performed a diagnostic accuracy study using a panel of sera from patients with hepatic CE (n = 45 "liquid" content stages, n = 25 "solid" content stages) and non-CE focal liver lesions (n = 54 with "liquid" content, n = 11 with "solid" content). The diagnosis and staging of CE were based on ultrasound (gold standard). Nine commercial seroassays (5 ELISA, 2 WB, 1 Chemiluminescence Immunoassay [CLIA] and 1 Immunochromatographic test [ICT]) were the index tests. Sensitivity (Se) ranged from 43 to 94% and from 31 to 87%, and specificity (Sp) from 68 to 100% and from 94 to 100%, when borderline results were considered positive or negative, respectively. Three seroassays (2 ELISA, 1 WB) were excluded from further analyses due to poor performances. When tests were combined, Sp was 98-100%. The best results were obtained using the WB-LDBIO alone (Se 83%) or as a third test after two non-WB tests (Se 67-86%). A validated WB or two non-WB tests, read with stringent criteria (borderline = negative and considered positive only if concordant positive), possibly confirmed by the WB, appear sensible approaches.

Evaluation of Nine Commercial Serological Tests for the Diagnosis of Human Hepatic Cyst Echinococcosis and the Differential Diagnosis with Other Focal Liver Lesions: A Diagnostic Accuracy Study

Bisoffi, Zeno;
2021-01-01

Abstract

The differential diagnosis of hepatic cystic echinococcosis (CE) may be challenging. When imaging is insufficient, serology can be applied, but no consensus diagnostic algorithm exists. We evaluated the performances of nine serological tests commercialized in Europe for the diagnosis of "echinococcosis". We performed a diagnostic accuracy study using a panel of sera from patients with hepatic CE (n = 45 "liquid" content stages, n = 25 "solid" content stages) and non-CE focal liver lesions (n = 54 with "liquid" content, n = 11 with "solid" content). The diagnosis and staging of CE were based on ultrasound (gold standard). Nine commercial seroassays (5 ELISA, 2 WB, 1 Chemiluminescence Immunoassay [CLIA] and 1 Immunochromatographic test [ICT]) were the index tests. Sensitivity (Se) ranged from 43 to 94% and from 31 to 87%, and specificity (Sp) from 68 to 100% and from 94 to 100%, when borderline results were considered positive or negative, respectively. Three seroassays (2 ELISA, 1 WB) were excluded from further analyses due to poor performances. When tests were combined, Sp was 98-100%. The best results were obtained using the WB-LDBIO alone (Se 83%) or as a third test after two non-WB tests (Se 67-86%). A validated WB or two non-WB tests, read with stringent criteria (borderline = negative and considered positive only if concordant positive), possibly confirmed by the WB, appear sensible approaches.
2021
Echinococcus granulosus s.l.; cystic echinococcosis; diagnostic accuracy; differential diagnosis; focal liver lesions; serodiagnosis; serology
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1035664
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 14
social impact