Background. Linear flow during cardiopulmonary bypass is considered a potential mechanism of lung damage in patients with chronic obstructive pulmonary disease (COPD). We evaluated differences in lung function of patients with COPD undergoing preoperative intraaortic balloon pumping (IABP), between linear flow during cardiopulmonary bypass (IABP-off) and maintenance of pulsatile flow (IABP-on at automatic 80 bpm) during cardioplegic arrest.Methods. Fifty patients with COPD undergoing preoperative IABP were randomized between January 2004 and July 2005 to receive nonpulsatile cardiopulmonary bypass with IABP discontinued during cardioplegic arrest (25 patients; group A), or IABP-induced pulsatile cardiopulmonary bypass (25 patients; group B). Hospital outcome, need for noninvasive ventilation, oxygenation (partial pressure of oxygen, arterial to fraction of inspired oxygen [PaO2/FIO2]), respiratory system compliance, and scoring of chest radiographs were compared.Results. There were no hospital deaths, no IABP-related complications, and no differences in postoperative noninvasive ventilation (group A: 6 of 25, 24.0% vs group B: 5 of 25, 20%; p = not significant [NS]). One patient in both groups developed pneumonia (p = NS). intensive care and hospital stay were comparable (p = NS). Group B showed lower intubation time (8.3 +/- 5.1 hours versus group A: 13.2 +/- 6.0; p = 0.001), better PaO2/FIO2 at aortic declamping (369.5 +/- 93.7 mm Hg vs 225.7 +/- 99.3; p = 0.001) at admission in intensive care (321.3 +/- 96.9 vs 246.2 +/- 109.7; p = 0.003), and at 24 hours (349.8 +/- 100.4 vs 240.8 +/- 77.3; p = 0.003). The respiratory system compliance was better in group B at the end of surgery (56.4 +/- 8.2 mL/cm H2O vs 49.4 +/- 7.0; p = 0.004) and 8 hours postoperatively (76.4 +/- 8.2 vs 59.4 +/- 7.0; p = 0.0001), as well as scoring of chest radiograph at intensive care admission (0.20 +/- 0.41 vs 0.38 +/- 0.56; p = 0.05) and on the first day (0.26 +/- 0.45 vs 0.50 +/- 0.67; p = 0.025).Conclusions. Automatic 80 bpm IABP during cardioplegic arrest preserves lung function in patients with COPD.

Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease

Onorati, Francesco;
2006-01-01

Abstract

Background. Linear flow during cardiopulmonary bypass is considered a potential mechanism of lung damage in patients with chronic obstructive pulmonary disease (COPD). We evaluated differences in lung function of patients with COPD undergoing preoperative intraaortic balloon pumping (IABP), between linear flow during cardiopulmonary bypass (IABP-off) and maintenance of pulsatile flow (IABP-on at automatic 80 bpm) during cardioplegic arrest.Methods. Fifty patients with COPD undergoing preoperative IABP were randomized between January 2004 and July 2005 to receive nonpulsatile cardiopulmonary bypass with IABP discontinued during cardioplegic arrest (25 patients; group A), or IABP-induced pulsatile cardiopulmonary bypass (25 patients; group B). Hospital outcome, need for noninvasive ventilation, oxygenation (partial pressure of oxygen, arterial to fraction of inspired oxygen [PaO2/FIO2]), respiratory system compliance, and scoring of chest radiographs were compared.Results. There were no hospital deaths, no IABP-related complications, and no differences in postoperative noninvasive ventilation (group A: 6 of 25, 24.0% vs group B: 5 of 25, 20%; p = not significant [NS]). One patient in both groups developed pneumonia (p = NS). intensive care and hospital stay were comparable (p = NS). Group B showed lower intubation time (8.3 +/- 5.1 hours versus group A: 13.2 +/- 6.0; p = 0.001), better PaO2/FIO2 at aortic declamping (369.5 +/- 93.7 mm Hg vs 225.7 +/- 99.3; p = 0.001) at admission in intensive care (321.3 +/- 96.9 vs 246.2 +/- 109.7; p = 0.003), and at 24 hours (349.8 +/- 100.4 vs 240.8 +/- 77.3; p = 0.003). The respiratory system compliance was better in group B at the end of surgery (56.4 +/- 8.2 mL/cm H2O vs 49.4 +/- 7.0; p = 0.004) and 8 hours postoperatively (76.4 +/- 8.2 vs 59.4 +/- 7.0; p = 0.0001), as well as scoring of chest radiograph at intensive care admission (0.20 +/- 0.41 vs 0.38 +/- 0.56; p = 0.05) and on the first day (0.26 +/- 0.45 vs 0.50 +/- 0.67; p = 0.025).Conclusions. Automatic 80 bpm IABP during cardioplegic arrest preserves lung function in patients with COPD.
2006
Aged
Cardiopulmonary Bypass
Cardiotonic Agents
Coronary Stenosis
Enoximone
Female
Forced Expiratory Volume
Hospital Mortality
Humans
Intraoperative Complications
Lung
Lung Compliance
Male
Middle Aged
Myocardial Infarction
Oxygen
Preoperative Care
Prospective Studies
Pulmonary Circulation
Pulmonary Disease, Chronic Obstructive
Pulsatile Flow
Respiration, Artificial
Treatment Outcome
Vital Capacity
Coronary Artery Bypass
Heart Arrest, Induced
Intra-Aortic Balloon Pumping
File in questo prodotto:
File Dimensione Formato  
Pulsatile_CPB_IABP_COPD_ATS2006.pdf

non disponibili

Tipologia: Versione dell'editore
Licenza: Accesso ristretto
Dimensione 274.34 kB
Formato Adobe PDF
274.34 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11562/1025539
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 29
social impact